Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-0533-2019Class II

Zimmer ZMS Intramedullary Fixation Smooth Guide Wire, 2.4 mm Diameter, 100 cm Length Item Number...

Zimmer GmbH / initiated 2018-10-22 / Terminated / root cause: packaging

Zimmer Biomet, Inc. began a recall of Zimmer ZMS Intramedullary Fixation Smooth Guide Wire, 2.4 mm Diameter, 100 cm Length Item Number: 47-2237-033-00 Product Usage: A single use surgical... on . FDA classified it as Class II and gives the reason as "Various Trauma Guide Wires- creases in the sealing area on the end opposite of the product's chevron opening compromising product sterility". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.

Recall record

Recall number
Z-0533-2019
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer GmbH
Product
Zimmer ZMS Intramedullary Fixation Smooth Guide Wire, 2.4 mm Diameter, 100 cm Length Item Number: 47-2237-033-00 Product Usage: A single use surgical instrument used during orthopaedic surgery for implantation of a prosthesis.
Product code
LXH Orthopedic Manual Surgical Instrument
Reason for recall
Various Trauma Guide Wires- creases in the sealing area on the end opposite of the product's chevron opening compromising product sterility
Root cause tag
packaging
FDA root cause
Packaging process control
Action
Zimmer Biomet conducted recall to distributors and hospital risk managers on 10/22/18, distributors notified via email. Hospital risk managers, as well as distributors with product, will be notified via Fed'X." Distributors responsibilities include:- Locating and removing the product in their territory, as well as identifying hospitals with fielded inventory. Distributors will return on-hand product to Zimmer Biomet and ensure all of their products are accounted for using the form provided in the letter. Hospital risk managers will be provided with a letter identifying the issue and their responsibilities. These responsibilities include: Ensuring affected personnel are aware of the notice contents - Assisting the Zimmer Biomet sales representative with the quarantine of the affected products. Certificate of Acknowledgement complete and send to [email protected]. This form must be returned even if you do not have affected products at your facility. Questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday
Quantity in commerce
2080
Distribution
Worldwide - US Nationwide Distribution Foreign: CANADA AUSTRALIA BRAZIL CHILE HONG KONG JAPAN MALAYSIA NETHERLANDS NICARAGUA SINGAPORE TAIWAN
Product codes and lots
All lots expiring prior to September 30, 2023

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0533-2019
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0530-2019Class IITerminatedVoluntary: Firm initiated
Z-0531-2019Class IITerminatedVoluntary: Firm initiated
Z-0532-2019Class IITerminatedVoluntary: Firm initiated
Z-0533-2019Class IITerminatedVoluntary: Firm initiated
Z-0534-2019Class IITerminatedVoluntary: Firm initiated
Z-0535-2019Class IITerminatedVoluntary: Firm initiated
Z-0536-2019Class IITerminatedVoluntary: Firm initiated
Z-0537-2019Class IITerminatedVoluntary: Firm initiated
Z-0538-2019Class IITerminatedVoluntary: Firm initiated
Z-0539-2019Class IITerminatedVoluntary: Firm initiated
Z-0540-2019Class IITerminatedVoluntary: Firm initiated
Z-0541-2019Class IITerminatedVoluntary: Firm initiated