Avenir Muller Stem Standard, uncemented HA, 1, Taper 12/14 Item Number: 01.06010.001 -
Zimmer GmbH began a recall of Avenir Muller Stem Standard, uncemented HA, 1, Taper 12/14 Item Number: 01.06010.001 - Product Usage: Avenir@ Muller Stems are intended to reduce pain and... on . FDA classified it as Class II and gives the reason as "Mislabeled Labeled Avenir Mller Stem size 1, the stem inside the packaging is an Avenir Mller Stem size 2". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0644-2019
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- Avenir Muller Stem Standard, uncemented HA, 1, Taper 12/14 Item Number: 01.06010.001 - Product Usage: Avenir@ Muller Stems are intended to reduce pain and increase hip mobility through long term cementless fixation of total or hemi hip arthroplasty in the femur of patients with an adequate bone stock to support the component. A system consisting of a stem, a ball head and a cup is used for the treatment of degenerative diseases or trauma of the hip. All Avenir Muller Stems are intended to provide connection to articulation with specified ball heads through the 12/14 taper. The stems may be used for total hip and hemi-hip arthroplasty. During total hip arthroplasty, the stems may be combined with constrained or semi-constrained acetabular systems.
- Product code
- LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
- Reason for recall
- Mislabeled Labeled Avenir Mller Stem size 1, the stem inside the packaging is an Avenir Mller Stem size 2 .
- Root cause tag
- manufacturing process
- FDA root cause
- Process control
- Action
- Zimmer Biomet issued Notices to the OUS consignees on October 31, 2018. Letter identifies action to be taken: Review this notice and ensure that affected personnel are aware of the contents. 2. If you have affected product at your facility, assist your Zimmer Biomet sales representative and quarantine all affected product. Your Zimmer Biomet sales representative will remove the affected product from your facility. 3. Complete Attachment 1 Certificate of Acknowledgement
- Quantity in commerce
- 13 units
- Distribution
- International distribution in the countries of Germany and Switzerland.
- Product codes and lots
- Lot Number:2955599 UDI Number:(01) 00889024479456(17)230831(10)2955599
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0644-2019 | Class II | Terminated | Voluntary: Firm initiated |