Z-0657-2019Class II

Reliance LITe Nerve Hook Bayoneted, 90, Blunt Tip, REF # 48066103 The blunt probe can be used as a...

Howmedica Osteonics Corp / initiated 2018-11-26 / Terminated

Howmedica Osteonics Corp. began a recall of Reliance LITe Nerve Hook Bayoneted, 90, Blunt Tip, REF # 48066103 The blunt probe can be used as a conventional means of achieving nerve retraction. The bend... on . FDA classified it as Class II and gives the reason as "Instead of having a spherical diameter, the probe was observed to have 2 radii and a flat surface. Additionally, upon further investigation, it was observed that some parts exhibited an edge on the intersection between...". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-0657-2019
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Howmedica Osteonics Corp
Product
Reliance LITe Nerve Hook Bayoneted, 90, Blunt Tip, REF # 48066103 The blunt probe can be used as a conventional means of achieving nerve retraction. The bend at the proximal tip of the ring the discectomy, as well as during the insertion of an IBD during a conventional TLIF procedure.
Product code
LXH Orthopedic Manual Surgical Instrument
Reason for recall
Instead of having a spherical diameter, the probe was observed to have 2 radii and a flat surface. Additionally, upon further investigation, it was observed that some parts exhibited an edge on the intersection between the radius and the diameter of the probe.
FDA root cause
Under Investigation by firm
Action
The firm, Stryker, sent an "Urgent Medical Device Recall" letter dated 11/14/2018 to its customers on 11/26/2018. The letter described product, problem and actions to be taken. The customers were instructed to: Examine your inventory; Immediately quarantine the affected product; and complete customer response form to Stryker Spine at email: [email protected]. For questions contact Manager-Regulatory Compliance & Quality System at 866-45-SPINE (77463)..
Quantity in commerce
39
Distribution
Worldwide distribution: US Distribution to the state of: PA and countries of:: Australia, Canada, France, Italy, Netherlands, Poland, and Spain.
Product codes and lots
Lot #s 183432, 183433, 183434, 17E168

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0657-2019
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0657-2019Class IITerminatedVoluntary: Firm initiated