JOURNEY II XR TIBIAL POSTERIOR KEEL PUNCH SZ 1-2 , REF 74013986 The JOURNEY II XR Tibial Posterior Keel Punch...
Smith & Nephew, Inc. began a recall of JOURNEY II XR TIBIAL POSTERIOR KEEL PUNCH SZ 1-2 , REF 74013986 The JOURNEY II XR Tibial Posterior Keel Punch is a reusable surgical instrument used to prepare... on . FDA classified it as Class II and gives the reason as "Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-1042-2019
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Smith & Nephew, Inc.
- Product
- JOURNEY II XR TIBIAL POSTERIOR KEEL PUNCH SZ 1-2 , REF 74013986 The JOURNEY II XR Tibial Posterior Keel Punch is a reusable surgical instrument used to prepare the proximal tibial to receive a JOURNEY II XR tibial baseplate.
- Product code
- JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
- Reason for recall
- Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- The firm, smith&nephew, initiated the recall by email with an "Urgent Medical Device Recall Notice" letter dated 12/10/18 to the customers on 12/10/2018. Letter describes the product, problem and actions to be taken. The customers were instructed to do the following: -Inspect your inventory and locate any devices from the listed product and batch numbers and quarantine them immediately. - If you are a distributor, you must notify your customers of the field action and ensure that these actions are carried out. -Complete and return the Response Form to [email protected] or fax to 901-566-7975. Please Note even if you have no product to return, this form must be completed, signed and returned. If you have any questions or concerns regarding this recall please contact [email protected].
- Quantity in commerce
- 65 units
- Distribution
- US Distribution to OR and TN; and Internationally to: Japan.
- Product codes and lots
- Batch Numbers: 17JGA0020; 17JGA0020A; 17JGA0020B; 17JGA0026; 17JGA0026A; 17JGA0026B; 17JGA0032A; 17JGA0032B; 17JGA0042; 17JGA0042A; 17JGA0042R
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1042-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1043-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1044-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1045-2019 | Class II | Terminated | Voluntary: Firm initiated |