Z-0832-2019Class II

COBRA FUSION 150 Ablation System (International Only), Catalog # (REF) 700-001MI

AtriCure, Inc. / initiated 2019-01-22 / Terminated

AtriCure, Inc. began a recall of COBRA FUSION 150 Ablation System (International Only), Catalog # (REF) 700-001MI on . FDA classified it as Class II and gives the reason as "There is a potential for patients undergoing ablation to experience an elevated risk for TE; during stand-alone off-pump procedures where cardio pulmonary bypass (CPB) was not utilized". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-0832-2019
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
AtriCure, Inc.
Product
COBRA FUSION 150 Ablation System (International Only), Catalog # (REF) 700-001MI
Product code
OCL Surgical Device, For Cutting, Coagulation, And/Or Ablation Of Tissue, Including Cardiac Tissue
Reason for recall
There is a potential for patients undergoing ablation to experience an elevated risk for TE; during stand-alone off-pump procedures where cardio pulmonary bypass (CPB) was not utilized.
FDA root cause
Unknown/Undetermined by firm
Action
On January 22, 2019, AtriCure distributed URGENT Advisory Notices to customers via certified mail. AtriCure is providing modifications to the existing Cobra Fusion Instruction for Use (IFU), to address contributing TE Factors associated with stand-alone off-pump procedures. These are in addition to the warnings and precautions that are present within the current IFU. Modifications to Warnings: When utilizing the Cobra Fusion device in a stand-alone off-pump (without CPB) procedure, the following should be considered: - Physicians should consider a comprehensive anti-coagulation protocol including pre-operative, intra-operative and post-operative anti-coagulation management to prevent potential thromboemboli. Modifications to Precautions: - Post-operative anti-coagulation therapy for protection against thromboemboli is inclusive of the bridging period between the end of the procedure and until effective therapeutic levels of Oral Anticoagulation (OAC) are achieved. Customers Should Take the following Action: - Read and follow the revised Instructions for Use IFU enclosed with the notification letter when using the Cobra Fusion. - Report any post ablation thromboembolic event with the Cobra Fusion, to AtriCure by phone at 1-866-349-2342 (select option 6) or e-mail to [email protected]. - Return the completed Acknowledgement Form. Contact Information: If you have any questions, please contact Rob Cantu, Vice President of Quality at (1-513-644-4245) from 9-6pm ET on Mondays - Fridays. You may also contact customer service at (1-866-349-2342) any time of day, your message will be forwarded to Quality Assurance for review promptly. **Press Release will be issue depended on CDRH comment/review**
Quantity in commerce
765 units
Distribution
AL, AR, AZ, CA, CT, CO, FL, ID, IL, IN, KS, KY, LA, MD, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NV, NY, OH, OK, OR, PA, SC, TN, TX, UT, VA, WA & WI Internationally - Germany, Italy, Netherlands, France, Austria, United Kingdom, Poland, Czech Republic, United Arab Emirates, Sweden, Switzerland, Kuwait, Belgium and Latvia
Product codes and lots
UDI - 00818354013016 Lot Numbers - All lots within expiry

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0832-2019
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0829-2019Class IITerminatedVoluntary: Firm initiated
Z-0830-2019Class IITerminatedVoluntary: Firm initiated
Z-0831-2019Class IITerminatedVoluntary: Firm initiated
Z-0832-2019Class IITerminatedVoluntary: Firm initiated