Z-1751-2019Class II
Prestige II, Prestige SI, Prestige VH Prestige system is a new multi-purpose conventional and digital R/F...
GE Healthcare / initiated 2019-03-29 / Terminated / root cause: design
GE Healthcare, LLC began a recall of Prestige II, Prestige SI, Prestige VH Prestige system is a new multi-purpose conventional and digital R/F remote controlled system on . FDA classified it as Class II and gives the reason as "There has been a reported incident of a Distar CRT monitor that has fallen off the monitor wall mount related to product aging". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-1751-2019
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- GE Healthcare
- Product
- Prestige II, Prestige SI, Prestige VH Prestige system is a new multi-purpose conventional and digital R/F remote controlled system.
- Product code
- JAA System, X-Ray, Fluoroscopic, Image-Intensified
- Reason for recall
- There has been a reported incident of a Distar CRT monitor that has fallen off the monitor wall mount related to product aging.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- On March 29, 2019, GE Healthcare sent an "URGENT MEDICAL DEVICE CORRECTION" letter dated March 29, 2019 to its consignees/customers. The letter described the product, problem and actions to be taken. Customers were instructed to do the following: Please follow the precautions below until the monitor feet on your unit are replaced: -The CRT monitor and suspension should be inspected and used with caution. Make sure the monitors are secured properly to the tray before each use. -Immediately stop using the system if any looseness of the monitor is noticed and contact your GE service representative. -Monitor should not be positioned directly above the patient. -Before service or preventative maintenance of the monitor is attempted, review the service and preventive maintenance procedures. Also the customer were instructed to complete and return the MEDICAL DEVICE NOTIFICATION ACKNOWLEDGEMENT RESPONSE REQUIRED form by scanning or taking a photo of the completed form e-mailing to: [email protected]. F/U visits by GE Healthcare will be made to replace the plastic feet. If you have any questions or concerns regarding this notification, please contact GE Healthcare Service at 1-800-437-1171 or your local Service Representative.
- Quantity in commerce
- 825 (38 US and 787 OUS) in total
- Distribution
- Worldwide Distribution: US (nationwide) to states of: AL, CA, CT, FL, GA, HI, IL, LA, MD, MI, MN, MO, NH, NY, OK, PA, TN, and VA; and countries of: Algeria, Argentina, Belgium, Bosnia & Herzegovina, Brazil, Bulgaria, Canada, China, Costa Rica, Cote D'Ivoire, Cyprus, Czech Republic, Egypt , France, French Polynesia, Germany, Greece, Guadeloupe, Guyana, Hungary, Italy, Japan, Korea, Lebanon, Mexico, Morocco, New Caledonia, Norway , Poland, Portugal, Russia, Saudi Arabia,Slovakia, Spain, Taiwan, Tunisia, Turkey, Ukraine, United Kingdom, Venezuela, and Vietnam.
- Product codes and lots
- Prestige II 030133RX32; 080053RX11; 080083RX17; 082408010027; 082408030060A; 082408040021; 082408040036; 082408040037; 082408040044; 082408040045; 082408040047; 082408040048; 082408060005; 082408080006; 082408100070; 082408120030; 082408120032; 082408120033; 082408120037; 082408160055; 082408160056; 082408190006; 082408210030; 082408270027; 0850080431; 0850080628; 0850080701; 0853080153; 0859080008; 209524GR2; 209577PRES; 24646PRESTIGE; 306766BRF2; 3347934R4; 3641PRESTIGE; 388008783XRMET; 38808761XRMET; 38808793XRAND; 38808793XRAND; 38842588XRMET; 38875194XRMET; 38875194XROCC; 3888773XRMET; 38894987XRCTR; 4813MPH; 48660; 519767REM; 519843REM; 540332RM7XXXXX; 60001PRESHM; 600126RX02; 705567VH; 705848REM; 757827RM6; 773854PREST; 84917; 84929; 89763; 902863AREM2; 905871REM; A5371104; A5753801; B5363103; BG4029RX03; BR48660; CS1019RX01; CS1156RX04; DZ1061RX01; EG1251RX01; HC5651XR04; M1828910; M4144612; M4163020; M4198029; M4484605; M5505607; M6042402; PL1507RX01; PPR31321; RU1152RX01; RU1884RX01; SA1231RX03; and X6004701. Prestige SI 2473; 010028RX09; 030024RX13; 030057RX09; 030115RX05; 030309RX08; 030309RX09; 030392RX04; 030488RX01; 040158RX02; 0530863PRE; 06004FLU03; 080100RX04; 080100RX05; 082408050009; 0850080345; 0853080139; 100800RX01; 110018RX05; 160015RX01; 190800RX01; 203573RAD7; 306359ARF1; 38821595XRMET; 38824949XRSOR; 38839875XRSOR; 412343F1; 412343F2; 504380LP2; 506357RF1; 506648RM12A; 514263PRESTIGE; 558039PRESTXT; 600036RX01; 615791W2; 707546XRAY2; 722015002; 808599PRESSI; 902428CRM3349A; 905895RM2; 909580PRESTIGE; 920051; 960025RX01; A1082408; A1111504; A1248010; A1265010; A1300409; A1350106; A1420001; A1532607; A1558706; A1586508; A1586513; A1599005; A1662507; A1767009; A1795401; A1898509; A1962801; A2032101; A2035102; A2072101; A2759005; A2788801; A5109204; A5131828; A5143004; A5145912; A5155124; A5156906; A5186206; A5196319; A5197202; A5216505; A5221505; A5238508; A5269712; A5270003; A5290803; A5323803; A5324803; A5330901; A5354602; A5356913; A5356917; A5358101; A5389206; A5395703; A5396001; A5397405; A5400801; A5400902; A5401303; A5419502; A5637603; A5674401; A5727602; A5807111; A5811711; A5811808; A5814112; A5814401; A6007701; A6014906; A6022104; A6035911; A6038301; A6039707; A6047607; A9884911; A9884912; AP3408XR07; AP4502XR06; B1098609; B1111504; B1222409; B1265010; B1303706; B1485001; B1500413; B1852311; B1989906; B2405502; B2485208; B5115215; B5119102; B5125307; B5127223; B5144909; B5174302; B5174303; B5174304; B5346201; B5374209; B5810209; B6047606; B98689601; BA4001RX01; BA4014RX01; C1074204; C1265006; C1282404; C1607006; C1737601; C5119102; C5129901; C9862608; CE268642; CI1040RX01; CY1010RX01; D1502404; D1598808; D1648601; D4185515; D4185521; DEF99605; DP418833; DPN25102; DPN28001; DPN29001; DZ1014RX01; DZ1024RX01; E1680813; E5821402; EG1070RX01; EG1101RX01; F1669601; FEG60900; FPG22203; GP178304; H13061RF06; H2053RF07; H2197RF05; H2197RF06; J9546503; K1680801; LB1064RX03; LB1065RX01; M1011301; M1013607; M1022102; M1025510; M1033510; M1039405; M1041605; M1074204; M1076846; M1096508; M1098609; M1111504; M1118409; M1137308; M1143415; M1143910; M1192102; M1198105; M1214310; M1225208; M1276501; M1329202; M1388607; M1413612; M1455828; M1469807; M1478607; M1480502; M1522002; M1528409; M1532306; M1558705; M1596410; M1599216; M1625914; M1631806; M1634011; M1653809; M1662008; M1700914; M1711501; M1750209; M1760309; M177858605; M1790301; M1803405; M1806510; M1843404; M1890305; M1962812; M2004601; M2005916; M2050503; M2148216; M2184403; M220648601; M2228001; M224352303; M2324822; M2326003; M2521008; M2565202; M2569117; M2620201; M2624211; M2634202; M2635601; M2718125; M2844616; M2845211; M2845606; M2845611; M2845701; M2864108; M2978303; M4012002; M4020525; M4031057; M4035208; M4041509; M4047511; M4160103; M4172407; M4188810; M4190721; M4209911; M4265604; M4400706; M4460813; M4480505; M4481305; M4485913; M4491604; M4494703; M4548517; M4548519; M470416402; M4859008; M5480805; M5485805; M6001908; M6005406; M6006101; M6012910; M6021006; M6023801; M6024901; M6035913; M6039701; M6042507; M6046306; M6058808; M62631501; M66000404; M9171010; M9792805; MA1219RX01; NC1003RX01; PER09204; PF1017RX02; PL1113RX01; PPR11604; PPR15304; PPR40803; PPR64613; RU1021RX04; RU1032RX02; RU1076RX01; RU1332RX01; RU1591RX02; RU2296RX01; RU2380RX01; RU2417RX01; RU2433RX01; RU2450RX01; RU2460RX01; RU2461RX01; RU2498RX01; RU2592RX01; RU2658RX01; TN1007RX02; TN1009RX02; TN1027RX01; TN1045RX01; TN1055RX02; TN1063RX01; TN1064RX01; TN1072RX01; TN1113RX01; TN1192XR01; TN1211RX01; TN1241RX01; TN1242RX01; TN2001RX02; UK5025RX02; X103911801; X116483805; X128275410; X382885701; X626315001; YP158307; and YP607003. Prestige VH 1773; 00107FLU02; 00336FLU02; 00532FLU03; 010028RX11; 030133RX28; 030137RX08; 030220RX10;080076RX01; 080100RX13; 0853080148; 0853080152; 160012RX03; 190282RX11; 190905RX01; 306359BRF1; 30869; 318473RD3; 38897739XRMET; 418659PRESTIGE; 421PRESTIGE; 536692PRESTIGE; 55085PRESTIGE; 600001RX01; 724284R3; 75648PREST; 808599PRESVH; 819523PRESTIGE; 819879PRESTIGE; 852626PRESTIGE; 860646RF3; 902496REM; 902567PRESTIGE; A1041408; A1279206; A1737608; A1969506; A4463304; A5145724; A5203304; A5216811; A5216812; A5216813; A5216814; A5389610; A5401508; A5414301; A5416101; A5684502; A5811413; A6014902; A6033503; A6064710; A9190111; A9222217; B1039601; B1081908; B1680807; B1720210; B4195715; B5111113; B5266904; B5806715; B5811414; B9185602; B9185603; BG4557RX02; C1248003; C1790301; C1929402; CE673215; CE755A08; D4185519; D5195608; D9956808; DE641212; DE669613; DEG27403; DPM88102; E1484007; EG1039RX04; EG1060RX02; EG1205RX01; EG1214RX01; F5119108; FE416035; FE443837; FEC28A09; FP182A08; FPF64404; FPG26601; FPG30509; FPG44301; FPG58804; G5119101; GP1046RX06; H2036RF14; H2077VAS06; H4858958; K4858901; LB1045RX01; M1013504; M1013608; M1152607; M1185409; M1185412; M1282411; M1622804; M1658910; M1680808; M1796317; M1974117; M1997006; M2742217; M2755002; M2802745; M2802755; M4030501; M4031082; M4159445; M4162211; M4162718; M4175810; M4189606; M4191021; M4192006; M4195701; M4196906; M4205406; M4207303; M4209920; M4210233; M4210424; M4210507; M4398206; M4401013; M4464618; M4474709; M4476119; M4477112; M4482788; M4495709; M4500708; M4501203; M4515907; M5460623; M5484813; M6016708; M6018604; M6049211; M6053304; M9865703; ME244360; ME246208; ME667519; ME799809; MP239201; N4192923; NE655313; NO1108RX01; NPV20503; P4172815; P4172816; P4200408; PER51102; PL1096RX01; PL1636RX01; R4211467; R4211473; RU1032RX05; RU1318RX02; RU1457RX01; RU1467RX01; RU1704RX02; RU1944RX01; RU2154RX01; SA1049RX05; SA1050RX05; SA1159RX02; TN1015RX01; TN1118RX01; TN1122RX01; UK1034RX03; UP644104; X62005701; XE0007; XE0018; XE0019; XE0021; XE0022; and XE0024.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1751-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1752-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1753-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1754-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1755-2019 | Class II | Terminated | Voluntary: Firm initiated |