VITROS 250AT Chemistry System, Product Code 1758143, (UDI # 10758750000036)
Ortho-Clinical Diagnostics began a recall of VITROS 250AT Chemistry System, Product Code 1758143, (UDI # 10758750000036) Product Usage: Performs discrete clinical tests on serum, urine, and cerebral... on . FDA classified it as Class II and gives the reason as "Potential negative drift in Creatine Kinase (CK) results when used on the VITROS 250 and 350 Systems". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-1934-2019
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Ortho-Clinical Diagnostics, Inc.
- Product
- VITROS 250AT Chemistry System, Product Code 1758143, (UDI # 10758750000036) Product Usage: Performs discrete clinical tests on serum, urine, and cerebral spinal fluid specimens. Methodologies include colorimetric (CM), potentiometric (PM), rate (RT), and immuno-rate (IR) tests using multi-layered VITROS Slides.
- Product code
- JJE Analyzer, Chemistry (Photometric, Discrete), For Clinical Use
- Reason for recall
- Potential negative drift in Creatine Kinase (CK) results when used on the VITROS 250 and 350 Systems.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- On 08 April 2019, a customer letter (Ref. CL2019-090) was sent via FedEx overnight courier and/ or ORTHO PLUS e-Communications and and/or US Postal Service Priority Mail (for PO Boxes only) to either all customers who were shipped affected VITROS 250 or 350 Systems. This communication provided the following required actions: - As per the VITROS CK Slide Instructions for Use, perform Quality Control (QC) testing daily to help ensure the slides are performing within acceptable limits. - If QC results are outside of the established ranges, discard the cartridge and repeat QC testing using a fresh cartridge of VITROS CK Slides. - If multiple cartridges are loaded on the VITROS 250/350 System, daily QC testing must be performed for each cartridge prior to use. - Consider loading one cartridge of VITROS CK Slides on board your system at a time. - Complete and return the request form via fax to 1-888-557-3759. Foreign affiliates were informed by email on 08 April 2019 of the issue and instructed to notify affected consignees of the issue and appropriate actions to take.
- Quantity in commerce
- 57 units
- Distribution
- US Nationwide Distribution
- Product codes and lots
- All lots
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1933-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1934-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1935-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1936-2019 | Class II | Terminated | Voluntary: Firm initiated |