Z-1946-2019Class II
DVR Crosslock ePAK Screw Driver, Model Number 212000002
Zimmer GmbH / initiated 2019-05-28 / Terminated / root cause: packaging
Zimmer Biomet, Inc. began a recall of DVR Crosslock ePAK Screw Driver, Model Number 212000002 Product Usage: These DVR Express Disposable Instruments are used to facilitate implantation of... on . FDA classified it as Class II and gives the reason as "There is a potential for weak seals of the sterile packaging". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.
Recall record
- Recall number
- Z-1946-2019
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- DVR Crosslock ePAK Screw Driver, Model Number 212000002 Product Usage: These DVR Express Disposable Instruments are used to facilitate implantation of orthopedic medical devices in trauma.
- Product code
- HXX Screwdriver
- Reason for recall
- There is a potential for weak seals of the sterile packaging.
- Root cause tag
- packaging
- FDA root cause
- Under Investigation by firm
- Action
- Urgent Medical Device Recall notification letters dated 5/28/19 were sent to customers. The letter identified the affected product, problem and actions to be taken. If you have further questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of call center operating hours will receive a voicemail prompt or be transferred to an on-call representative in the event of an emergency.
- Quantity in commerce
- 3022 total
- Distribution
- Worldwide Distribution - US Nationwide: AL, AR, AZ, CA, CO, FL, GA, ID, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, NC, NE, NJ, NM, NY, OH OK, OR, PA, SC, TN, TX, UT, WA, WI, WV, and Puerto Rico. Products were distributed to the following foreign countries: Australia, Canada, Chile, Japan, Netherlands.
- Product codes and lots
- Lot Numbers: 235471 235472 235473 235474 235475 187762 193492 193493 193494 193495 193496 193565 BF10LBJ BFI0LBJ BFI0M9E BFI0N10 BFI0N11 BFI0P39 I0N0X I0N0XR I0N0Y I0N10 I0N11 I0N5B I0P39 225207 BFIOLBJ I0N5P
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1946-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1947-2019 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1948-2019 | Class II | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.