Z-1961-2019Class II

Comprehensive Reverse Shoulder Instrument Case Total (Outer Case Vault Only), Item Number 595510

Zimmer GmbH / initiated 2019-06-10 / Terminated / root cause: sterility

Zimmer Biomet, Inc. began a recall of Comprehensive Reverse Shoulder Instrument Case Total (Outer Case Vault Only), Item Number 595510 on . FDA classified it as Class II and gives the reason as "Lack of an adequate sterilization validation". As of , the recall status on record is Terminated, and MDM tags the root cause as sterility.

Recall record

Recall number
Z-1961-2019
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer GmbH
Product
Comprehensive Reverse Shoulder Instrument Case Total (Outer Case Vault Only), Item Number 595510
Product code
FSM Tray, Surgical, Instrument
Reason for recall
Lack of an adequate sterilization validation.
Root cause tag
sterility
FDA root cause
Under Investigation by firm
Action
Medical Device Recall notification letters dated 6/10/19 were sent to customers.
Quantity in commerce
1257
Distribution
The products were distributed US nationwide. The products were distributed to the following foreign countries: Argentina, Australia, Canada, Chile, China, Columbia, Costa Rica, Ecuador, India, Japan, Korea, Malaysia, Mexico, Netherlands, Thailand, Venezuela.
Product codes and lots
Lots: 251059  254986  203752 260646 263012 264753 2111048 2111052 2111050 2111051 21110107 21110106 21110117 2291017 2881019 3231032 2981046 3341019  831129 1961120  21110105  21110108  1961120  1961120  1961120  3461146  1961120  1961120  1961120  1961120  1961120  3461146  1081211  1081211  1081211  1951228  1951228  1951228  1951228  1951228  3181203  3181203  3181203  3181203  1411303  1411303¿ 1411303  1721312  1721312  1721312  2631353  2631353  3461146  MB33730  171421 1721312  ME50120  ME50130  1641404  MH50820  1641404  1641404  2331407  1721312  1961120  2291016  3461146  2331407  2331407  ML35700  2331407  2631048  ML56520  2331407  2331407  2331407  2331407  961509  961509 961509  961509  MO93600  MO93610  961509  961509  1631512  1631512  2261523  2261523  2261523  2681520  2681520  2681520  443894  2681520  443894  443894  476977  476977  501920  501920  530934  538816

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1961-2019
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1960-2019Class IITerminatedVoluntary: Firm initiated
Z-1961-2019Class IITerminatedVoluntary: Firm initiated