Z-0234-2020Class II

SPROTTE Lumbar with Introducer, labeled as the following: 1. Sprotte 22G x 90mm w/ introducer and wings...

Pajunk GmbH Medizintechnologie / initiated 2019-08-30 / Open, Classified / root cause: manufacturing process

Pajunk GmbH began a recall of SPROTTE Lumbar with Introducer, labeled as the following: 1. Sprotte 22G x 90mm w/ introducer and wings (25/box); 2. Sprotte 22G x 120mm w/ introducer and... on . FDA classified it as Class II and gives the reason as "Problem with packaging sealing process which affects sterility". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0234-2020
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Pajunk GmbH Medizintechnologie
Product
SPROTTE Lumbar with Introducer, labeled as the following: 1. Sprotte 22G x 90mm w/ introducer and wings (25/box); 2. Sprotte 22G x 120mm w/ introducer and wings (25/box); 3. Sprotte 19G x 90mm w/ introducer and wings (25/box]); 4. Sprotte 22G x 103mm w/ introducer and wings (25/box); 5. Sprotte 21G x 90mm w/ introducer and wings (25/box); 6. Sprotte 21G x 103mm w/ introducer and wings (25/box); 7. Sprotte 20G x 103mm w/ introducer and wings (25/box); 8. Sprotte 20G x 90mm w/ introducer and wings (25/box) Product Usage: The SPROTTE lumbar puncture needles are intended to gain entry into or puncture the spinal cavity permitting injection (including anesthesia) / withdrawal of fluids for purposes of diagnostic lumbar puncture, myelography/ discography procedures. The device is intended for adult and pediatric patients.
Product code
BSP Needle, Conduction, Anesthetic (W/Wo Introducer)
Reason for recall
Problem with packaging sealing process which affects sterility.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
Pajunk GmbH Medizintechnologie notified distributor and end customers on about 08/30/2019, via "Urgent Product Recall Notice" letters. Instructions included to immediately identify any affected products in inventory and quarantine them, cease use of affected products, and complete and return the Attachment B indicating receipt of the notice. Additionally end customers and distributors were instructed to provide the recall notice to all responsible personnel within the organization or if products were further distributed. Questions or concerns can be directed to Laura Roberts, Manager of Office of Operations and Client Relations, email [email protected], phone (470) 448-4075.
Quantity in commerce
40,475 devices
Distribution
Worldwide distributions - US Nationwide including the states of AR, AZ, CA, CO, CT, DC, FL, GA, IL, IN, LA, MA, MD, MI, MN, MO, NC, NJ, NY, OH, RI, SC, TN, TX, WI, WY. Countries of Germany, Ellada / Greece, Canada, Italy, Lietuva / Lithuania/ Litauen, Australia, Luxembourg, Austria, Nederland / Netherlands, Belgium, Polska / Poland, Switzerland, Sverige / Sweden, Czech Republic, Slovenija / Slovenia, Danmark / Denmark, Kroatien/ Croatia, Espa¿a / Spain, Aserbeidschan/ Azerbaidzan, Suomi / Finland, Brunei, France, Russland/ Russia, Great Britain, Oman, Israel.
Product codes and lots
Lot Numbers 1240 through 1313. Item numbers:   1. 321151-30C;   2. 331151-30C;   3. 321151-31C;   4. 341151-30C;   5. 321151-31A;   6. 341151-31A;   7. 341151-31B;   8. 331151-31B

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0234-2020
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0234-2020Class IIOngoingVoluntary: Firm initiated