The products involved are DeWALT laser distance measurers, model numbers DW0165, DW0165S, DW0330S and Stanley...
STANLEY BLACK & DECKER INC. began a recall of The products involved are DeWALT laser distance measurers, model numbers DW0165, DW0165S, DW0330S and Stanley Fatmax FMHT77506. These products were produced... on . FDA classified it as Class II and gives the reason as "The products are labeled as Class II lasers. However, the level of laser radiation emitted by the distributed products may exceed the limit (1 mW) established for Class II lasers. These products would be more...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-0681-2020
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Stanley Black & Decker Inc.
- Product
- The products involved are DeWALT laser distance measurers, model numbers DW0165, DW0165S, DW0330S and Stanley Fatmax FMHT77506. These products were produced for DeWALT and Stanley by a contract manufacturer.
- Product code
- RER Alignment Laser Product
- Reason for recall
- The products are labeled as Class II lasers. However, the level of laser radiation emitted by the distributed products may exceed the limit (1 mW) established for Class II lasers. These products would be more appropriately classified into laser Class IIIa (IEC Laser Class IIIR).
- Root cause tag
- labeling and UDI
- FDA root cause
- Radiation Control for Health and Safety Act
- Action
- The products are labeled as Class II lasers. However, the level of laser radiation emitted by the distributed products may exceed the limit ( I mnW) established for Class 11 lasers. These products would be more appropriately categorized in Class Ilia (IFEC Laser Class 3R).
- Quantity in commerce
- 13917
- Distribution
- Nationwide
- Product codes and lots
- The products involved are DeWALT laser distance measurers, model numbers DWO 165, DWO 1 65S, DW0330S and Stanley Fat Max FMHT77506 TLM 165. These products were produced for DeWALT and Stanley by a contract manufacturer..