Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-0681-2020Class II

The products involved are DeWALT laser distance measurers, model numbers DW0165, DW0165S, DW0330S and Stanley...

Stanley Black & Decker Inc. / initiated 2019-11-21 / Open, Classified / root cause: labeling and UDI

STANLEY BLACK & DECKER INC. began a recall of The products involved are DeWALT laser distance measurers, model numbers DW0165, DW0165S, DW0330S and Stanley Fatmax FMHT77506. These products were produced... on . FDA classified it as Class II and gives the reason as "The products are labeled as Class II lasers. However, the level of laser radiation emitted by the distributed products may exceed the limit (1 mW) established for Class II lasers. These products would be more...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-0681-2020
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Stanley Black & Decker Inc.
Product
The products involved are DeWALT laser distance measurers, model numbers DW0165, DW0165S, DW0330S and Stanley Fatmax FMHT77506. These products were produced for DeWALT and Stanley by a contract manufacturer.
Product code
RER Alignment Laser Product
Reason for recall
The products are labeled as Class II lasers. However, the level of laser radiation emitted by the distributed products may exceed the limit (1 mW) established for Class II lasers. These products would be more appropriately classified into laser Class IIIa (IEC Laser Class IIIR).
Root cause tag
labeling and UDI
FDA root cause
Radiation Control for Health and Safety Act
Action
The products are labeled as Class II lasers. However, the level of laser radiation emitted by the distributed products may exceed the limit ( I mnW) established for Class 11 lasers. These products would be more appropriately categorized in Class Ilia (IFEC Laser Class 3R).
Quantity in commerce
13917
Distribution
Nationwide
Product codes and lots
The products involved are DeWALT laser distance measurers, model numbers DWO 165, DWO 1 65S, DW0330S and Stanley Fat Max FMHT77506 TLM 165. These products were produced for DeWALT and Stanley by a contract manufacturer..

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0681-2020
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0681-2020Class IIOngoingFDA Mandated