Reinforced Introducer Sets Maquet 8 Fr., Part Number: 068400040310. It is an accessory to be used for...
Datascope Corporation began a recall of Reinforced Introducer Sets Maquet 8 Fr., Part Number: 068400040310. It is an accessory to be used for percutaneous insertion of MAQUET IntraAortic Balloon... on . FDA classified it as Class II and gives the reason as "Potential for compromised sterility in breached pouches of specific lots of Reinforced Introducer Sets Maquet 7 Fr., 7.5 Fr. and 8 Fr. IABs". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.
Recall record
- Recall number
- Z-0934-2020
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Datascope Corp.
- Product
- Reinforced Introducer Sets Maquet 8 Fr., Part Number: 068400040310. It is an accessory to be used for percutaneous insertion of MAQUET IntraAortic Balloon Catheters.
- Product code
- DSP System, Balloon, Intra-Aortic And Control
- Reason for recall
- Potential for compromised sterility in breached pouches of specific lots of Reinforced Introducer Sets Maquet 7 Fr., 7.5 Fr. and 8 Fr. IABs.
- Root cause tag
- packaging
- FDA root cause
- Package design/selection
- Action
- On December 11, 2019 the firm distributed Urgent Medical Device Recall Communication letters by FedEx 2 day delivery with signature proof of delivery stating: URGENT MEDICAL DEVICE RECALL REMOVAL MAQUET 7Fr., 7.5Fr. and 8Fr. REINFORCED INTRODUCER SETS PLEASE FORWARD THIS INFORMATION TO ALL CURRENT AND POTENTIAL USERS OF REINFORCED INTRODUCER SETS FOR MAQUET 7 Fr., 7.5 Fr. AND 8 Fr. INTRA-AORTIC BALLOON (IAB) WITHIN YOUR HOSPITAL OR FACILITY. IF YOU HAVE FURTHER DISTRIBUTED ANY OF THE AFFECTED PRODUCTS, FORWARD THIS INFORMATION TO THE RECIPIENT. Dear Risk Manager, Datascope / Maquet Getinge is initiating a voluntary Medical Device Recall Removal of the Reinforced Introducer Sets for Maquet 7 Fr., 7.5 Fr.and 8 Fr. IAB (Intra Aortic Balloon) due to a potential breach in the Mylar side (clear plastic) of the pouch, which could compromise device sterility. Identification of the issue: During the execution of a remediation protocol for re-verification of packaging, Datascope / Maquet Getinge found a small slit on the Mylar side (clear plastic) of the pouch of one device. Imprints of the sharp corners of the polystyrene strip used in packaging were observed around the slit, which likely caused the breach in the pouch compromising the sterility of the device. Risk to Health Adequate packaging and packaging materials are essential to help preserve the sterility of medical devices. Improperly sterilized medical devices may pose a serious risk of patient infection, including pyrogenic reaction, inflammatory response, and the possibility of a deadly infection. The probability of serious injury or illness occurring as a result of this potential issue is unlikely, however, likelihood is greater for immunocompromised patients. To date, Datascope / Maquet Getinge has not received any complaints, nor have any adverse events been reported resulting in serious illness or injuries caused by the Reinforced Introducer Set for Maquet 7 Fr., 7.5 Fr.
- Quantity in commerce
- 523
- Distribution
- US: AK AL AZ CA CO CT FL GA IA ID IL IN KS KY LA MD MI MN MO MS NC ND NE NJ NY OH OK PA SC SD TN TX VA WA WI WV OUS: Switzerland, Netherlands, South Africa, Canada, Germany, Austria, Spain, Italy, Poland, Bharain, Malaysia
- Product codes and lots
- Part Number: 068400040310 UDI: 10607567107943 (068400040310) Lot Codes: 3000079612, 3000043101, 3000036631, 3000015016, TTP.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0932-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0933-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0934-2020 | Class II | Terminated | Voluntary: Firm initiated |