Z-1404-2020Class II
MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Compass 10, Sterile...
Terumo Cardiovascular Systems Corporation / initiated 2019-11-22 / Terminated / root cause: manufacturing process
Microvention, Inc. began a recall of MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Compass 10, Sterile, Rx, REF numbers 100203CMSR-V, 100408CMSR-V... on . FDA classified it as Class II and gives the reason as "The devices may be missing the implant coil". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-1404-2020
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Terumo Cardiovascular Systems Corporation
- Product
- MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Compass 10, Sterile, Rx, REF numbers 100203CMSR-V, 100408CMSR-V, 100412CMSR-V, 100510CMSR-V, 100516CMSR-V, 100612CMSR-V, 100618CMSR-V, and 100721CMSR-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Product code
- HCG Device, Neurovascular Embolization
- Reason for recall
- The devices may be missing the implant coil.
- Root cause tag
- manufacturing process
- FDA root cause
- Process design
- Action
- The recalling firm issued letters beginning 11/22/2019 dated 11/26/2019 via email using different flags according to the region the foreign consignee was located, i.e. 'URGENT: FIELD SAFETY CORRECTION ACTION" (for EMEA), "URGENT: MEDICAL DEVICE RECALL" (for Japan), or "FIELD SAFETY ADVISORY NOTICE" (for Rest of World).
- Quantity in commerce
- 85 units
- Distribution
- All distribution was OUS. The countries receiving affected product are: Albania, Austria, Belarus, Belgium, Brazil, Bulgaria, China, Cyprus, Czech Republic, Denmark, Egypt, Finalnd, France, Georgia, Germany, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Korea, Latvia, Lebanon, Malta, Morocco, Netherlands, Norway, Poland, Portugal, Republic of Serbia, Romania, Russian Federation, Slovak Republic, Slovenia, South Africa, Spain, Sweden, Switzerland, Syria, Turkey, Ukraine, United Arab Emirates, and United Kingdom.
- Product codes and lots
- Catalog/lot numbers: 100203CMSR-V - 1903085WP; 100408CMSR-V - 1903085WP and 1904015PP; 100412CMSR-V - 1904225RP, 1905205QP, and 1904035PP; 100510CMSR-V - 1905205QP and 1904085WP; 100516CMSR-V - 1903135WP and 1905155WP; 100612CMSR-V - 1903225WP; 100618CMSR-V - 1903135QP and 1904085WP; and 100721CMSR-V - 1903085RP.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1392-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1393-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1394-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1395-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1396-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1397-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1398-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1399-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1400-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1401-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1402-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1403-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1404-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1405-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1406-2020 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1407-2020 | Class II | Terminated | Voluntary: Firm initiated |