Z-2206-2020Class II

Medtronic Implantable Insulin Pump System, REF: MMT-2007D, Sterile EO, CE 0459 UDI: 00763000043001

Medtronic, Inc. / initiated 2020-04-10 / Terminated / root cause: manufacturing process

Medtronic Inc. began a recall of Medtronic Implantable Insulin Pump System, REF: MMT-2007D, Sterile EO, CE 0459 UDI: 00763000043001 on . FDA classified it as Class II and gives the reason as "Internal testing results showed endotoxin-related test result did not meet specifications for implantable insulin pump. If pumps have higher than allowed endotoxin levels, patients may have an effect of fever...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2206-2020
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medtronic, Inc.
Product
Medtronic Implantable Insulin Pump System, REF: MMT-2007D, Sterile EO, CE 0459 UDI: 00763000043001
Product code
LKK Pump, Infusion, Implanted, Programmable
Reason for recall
Internal testing results showed endotoxin-related test result did not meet specifications for implantable insulin pump. If pumps have higher than allowed endotoxin levels, patients may have an effect of fever, hypotension, anaphylactic shock, hyperglycemia, or diabetic ketoacidosis (DKA), potentially followed by secondary multi-organ failure (primarily renal and hepatic) and/or death.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
Medtronic initiated verbal communication with affected consignees on April 10, 2020 via phone call and provided affected consignees with an "Urgent Field Safety Notice" via email between the dates of 04/24/20 - 4/30/20. . In addition to informing consignees about the recall, the firm asked consignees to take the following actions: 1. Immediately identify and quarantine all unused affected pumps in your inventory. 2. Return all unused affected pumps in your inventory to Medtronic. Your Medtronic Representative can assist you in the return and replacement of this pump as necessary. 3. Forward this notice to all those who need to be aware within your organization and to any organization where the affected pumps may have been transferred. Please maintain a copy of this notice in your records.
Quantity in commerce
24 Pumps
Distribution
No US Distribution. OUS: Netherlands, France, and Sweden
Product codes and lots
Device not distributed within the US. All Pump lots produced May 21, 2019 to present containing the following serial numbers: 31359, 31360, and 31332

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2206-2020
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2206-2020Class IITerminatedVoluntary: Firm initiated