Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-2321-2020Class II

A.L.P.S. PROXIMAL HUMERUS PLATING SYSTEM HIGH PLATE LEFT 14 HOLE 234MM, Item Number: 110030309 -

Zimmer GmbH / initiated 2020-05-14 / Terminated / root cause: design

Biomet began a recall of A.L.P.S. PROXIMAL HUMERUS PLATING SYSTEM HIGH PLATE LEFT 14 HOLE 234MM, Item Number: 110030309 - Product Usage: Intended for temporary internal fixation and... on . FDA classified it as Class II and gives the reason as "Distributed to the field without having completed design history files or design transfer activities". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-2321-2020
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer GmbH
Product
A.L.P.S. PROXIMAL HUMERUS PLATING SYSTEM HIGH PLATE LEFT 14 HOLE 234MM, Item Number: 110030309 - Product Usage: Intended for temporary internal fixation and stabilization of osteotomies and fractures during the normal healing process.
Product code
HRS Plate, Fixation, Bone
Reason for recall
Distributed to the field without having completed design history files or design transfer activities
Root cause tag
design
FDA root cause
Device Design
Action
Zimmmer Biomet issued Urgent Medical Device Recall letter , dated May 14, 2020 to Risk Manger, Distributors,Surgeons, stating reason for recall, health risk and action to take: 1. Review this notification and ensure that affected personnel are aware of the contents. 2. If you have affected product at your facility, assist your Zimmer Biomet sales representative and quarantine all affected product. Your Zimmer Biomet sales representative will remove the affected product from your facility. 3. Complete Attachment 1 Certificate of Acknowledgement and send to [email protected]. This form will be returned even if you do not have affected products at your facility. 4. Retain a copy of the acknowledgement form with your recall records in the event of a compliance audit of your facilitys documentation. 5. If you have further questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of call center operating hours will receive a voicemail prompt or be transferred to an on-call representative in the event of an emergency. Alternatively, your questions may be emailed to [email protected]. Surgeon Responsibilities: 1. Review this notification for awareness of the contents. 2. There are no specific patient monitoring instructions related to this recall that are recommended beyond your existing follow-up schedule.
Quantity in commerce
1 US
Distribution
Worldwide distribution - US Nationwide distribution including in the states of NY, GA, FL, MO and the countries of Canada, AUSTRALIA, CHILE, CHINA, JAPAN, MALAYSIA, NETHERLANDS.
Product codes and lots
Lot Number:  All lots expiring prior to December 31, 2026

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2321-2020
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2303-2020Class IITerminatedVoluntary: Firm initiated
Z-2304-2020Class IITerminatedVoluntary: Firm initiated
Z-2305-2020Class IITerminatedVoluntary: Firm initiated
Z-2306-2020Class IITerminatedVoluntary: Firm initiated
Z-2307-2020Class IITerminatedVoluntary: Firm initiated
Z-2308-2020Class IITerminatedVoluntary: Firm initiated
Z-2309-2020Class IITerminatedVoluntary: Firm initiated
Z-2310-2020Class IITerminatedVoluntary: Firm initiated
Z-2311-2020Class IITerminatedVoluntary: Firm initiated
Z-2312-2020Class IITerminatedVoluntary: Firm initiated
Z-2313-2020Class IITerminatedVoluntary: Firm initiated
Z-2314-2020Class IITerminatedVoluntary: Firm initiated
Z-2315-2020Class IITerminatedVoluntary: Firm initiated
Z-2316-2020Class IITerminatedVoluntary: Firm initiated
Z-2317-2020Class IITerminatedVoluntary: Firm initiated
Z-2318-2020Class IITerminatedVoluntary: Firm initiated
Z-2319-2020Class IITerminatedVoluntary: Firm initiated
Z-2320-2020Class IITerminatedVoluntary: Firm initiated
Z-2321-2020Class IITerminatedVoluntary: Firm initiated
Z-2322-2020Class IITerminatedVoluntary: Firm initiated
Z-2323-2020Class IITerminatedVoluntary: Firm initiated
Z-2324-2020Class IITerminatedVoluntary: Firm initiated