BOSS DeBakey "Gator-Grip" Needle Holder 2 mm tip, 9", Part Numbers 50-2503 and 51-2503 -

Boss Instruments, Ltd. / initiated 2020-06-26 / Terminated / root cause: manufacturing process

Boss Instruments, Ltd. began a recall of BOSS DeBakey "Gator-Grip" Needle Holder 2 mm tip, 9", Part Numbers 50-2503 and 51-2503 - Product Usage: Endoscopic cleaning brushes are single use devices... on . FDA classified it as Class II and gives the reason as "The tungsten carbide plate, which is intended to hold the sewing needle securely, can break when holding the sewing needle under pressure". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2767-2020
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Boss Instruments, Ltd.
Product
BOSS DeBakey "Gator-Grip" Needle Holder 2 mm tip, 9", Part Numbers 50-2503 and 51-2503 - Product Usage: Endoscopic cleaning brushes are single use devices intended to clean the interior of endoscopes after endoscopy procedures. The brush is threaded through the biopsy valve and pulled through the interior of the endoscope to remove debris.
Product code
FHQ Holder, Needle, Gastroenterologic
Reason for recall
The tungsten carbide plate, which is intended to hold the sewing needle securely, can break when holding the sewing needle under pressure.
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
Urgent Voluntary Medical Device Recall notification letters dated 6/26/20 were emailed to customers. Please distribute this information to any of your customers who may have these units in their possession and ask that they return them to Boss Instruments Ltd. for full credit by no later than August 3l5t, 2020. We also ask that any remaining units of this lot held in your current inventory be returned to us immediately for full credit. Please contact me directly at the email address listed below, call our toll free number: 1-540-832-5000 or contact your normal customer account manager so that we can assign you a returned goods authorization number (RGA#) and further assist you in return of the product noted above. Please note that replacements will be provided on a first come first serve bases and we are working with our supplier to make all replacement units available as soon as possible. We recognize that the withdrawal of these DeBakey needle holders may be disruptive to your facility and we apologize for any inconvenience this may cause. If you have any addition questions regarding this action or to report any customer complaints, please contact me at [email protected].
Quantity in commerce
96 devices
Distribution
Worldwide distribution - US Nationwide distribution including in the states of CA, TN, TX and the countries of England, Japan, New Zealand, South Africa, South Korea, Taiwan.
Product codes and lots
Lot Numbers: 00351415,00425391, 00374008,07702195, 08801812, 08802271, 00383211,00384765,00418258, 08804204,09900093, 09900383

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2767-2020
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2767-2020Class IITerminatedVoluntary: Firm initiated