Z-0002-2021Class II

Endo GIA Auto Suture Universal Articulating Loading Unit 30 mm - 2.5 mm, Item Code 030451 -

Medtronic, Inc. / initiated 2020-08-12 / Open, Classified / root cause: manufacturing process

Covidien, LP began a recall of Endo GIA Auto Suture Universal Articulating Loading Unit 30 mm - 2.5 mm, Item Code 030451 - Product Usage: The Endo GIA universal staplers have applications in... on . FDA classified it as Class II and gives the reason as "The device staples may not properly form upon application preventing adequate hemostasis. Use of a product with this assembly error may result in incomplete staple formation". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0002-2021
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Medtronic, Inc.
Product
Endo GIA Auto Suture Universal Articulating Loading Unit 30 mm - 2.5 mm, Item Code 030451 - Product Usage: The Endo GIA universal staplers have applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection and creation of anastomosis.
Product code
GDW Staple, Implantable
Reason for recall
The device staples may not properly form upon application preventing adequate hemostasis. Use of a product with this assembly error may result in incomplete staple formation.
Root cause tag
manufacturing process
FDA root cause
Under Investigation by firm
Action
Urgent Medical Device Recall notification letters dated 8/12/20 were sent to customers. Required Actions: 1.Please immediately quarantine and discontinue use of affected item codes with associated lot numbers listedon Attachment A. 2.Please return affected product as indicated below. All unused products from the affected item codes and associated lot numbers must be returned. 3.If you have distributed the Covidien Endo GIA" Auto Suture" universal articulating loading units listed on Attachment A, please promptly forward the information from this letter to those recipients. 4.Complete the Recalled Product Return Form even if you do not have inventory. We regret any inconvenience this may cause. We are committed to patient safety and appreciate your prompt attention to this matter. If you have any questions regarding this communication, please contact your Medtronic representative or Customer Service at 800-962-9888, option 2.
Quantity in commerce
900,007 total
Distribution
Worldwide distribution - US Nationwide and Global Distribution.
Product codes and lots
Lot Numbers:  T0A016X T8D009X T8E058X T8H024X T9D052X T0B130X T8D010X T8E069X T8H025X T9D149X T0D070X T8D012X T8H004X T8H061X T9E081X T7H001X T8D013X T8H008X T8M044X T9E082X T7L024X T8D041X T8H009X T9A032X T9F133X T7L025X T8D042X T8H010X T9A033X T9G029X T8B012X T8D043X T8H011X T9A082X T9G037X T8B013X T8D044X T8H012X T9B039X T9G085X T8C026X T8D045X T8H013X T9B040X T9G086X T8C027X T8D046X T8H014X T9D043X T9G093X T8C045X T8E049X T8H022X T9D050X T9K069X T8C046X T8E050X T8H023X T9D051X T9M069X T8C047X T8E057X

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0002-2021
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0001-2021Class IIOngoingVoluntary: Firm initiated
Z-0002-2021Class IIOngoingVoluntary: Firm initiated
Z-0003-2021Class IIOngoingVoluntary: Firm initiated
Z-0004-2021Class IIOngoingVoluntary: Firm initiated
Z-0005-2021Class IIOngoingVoluntary: Firm initiated
Z-0006-2021Class IIOngoingVoluntary: Firm initiated
Z-0007-2021Class IIOngoingVoluntary: Firm initiated
Z-0008-2021Class IIOngoingVoluntary: Firm initiated
Z-0009-2021Class IIOngoingVoluntary: Firm initiated