Z-0009-2021Class II

Covidien Best Practices Procedure Kits containing Auto Suture Endo GIA Universal Loading Units, Parent Codes...

Medtronic, Inc. / initiated 2020-08-12 / Open, Classified / root cause: manufacturing process

Covidien, LP began a recall of Covidien Best Practices Procedure Kits containing Auto Suture Endo GIA Universal Loading Units, Parent Codes 00Z2760 - Product Usage: The Endo GIA universal... on . FDA classified it as Class II and gives the reason as "The device staples may not properly form upon application preventing adequate hemostasis. Use of a product with this assembly error may result in incomplete staple formation". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0009-2021
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Medtronic, Inc.
Product
Covidien Best Practices Procedure Kits containing Auto Suture Endo GIA Universal Loading Units, Parent Codes 00Z2760 - Product Usage: The Endo GIA universal staplers have applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection and creation of anastomosis.
Product code
GDW Staple, Implantable
Reason for recall
The device staples may not properly form upon application preventing adequate hemostasis. Use of a product with this assembly error may result in incomplete staple formation.
Root cause tag
manufacturing process
FDA root cause
Under Investigation by firm
Action
Urgent Medical Device Recall notification letters dated 8/12/20 were sent to customers. Required Actions: 1.Please immediately quarantine and discontinue use of affected item codes with associated lot numbers listedon Attachment A. 2.Please return affected product as indicated below. All unused products from the affected item codes and associated lot numbers must be returned. 3.If you have distributed the Covidien Endo GIA" Auto Suture" universal articulating loading units listed on Attachment A, please promptly forward the information from this letter to those recipients. 4.Complete the Recalled Product Return Form even if you do not have inventory. We regret any inconvenience this may cause. We are committed to patient safety and appreciate your prompt attention to this matter. If you have any questions regarding this communication, please contact your Medtronic representative or Customer Service at 800-962-9888, option 2.
Quantity in commerce
900,007 total
Distribution
Worldwide distribution - US Nationwide and Global Distribution.
Product codes and lots
Lot Numbers:  00Z2117

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0009-2021
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0001-2021Class IIOngoingVoluntary: Firm initiated
Z-0002-2021Class IIOngoingVoluntary: Firm initiated
Z-0003-2021Class IIOngoingVoluntary: Firm initiated
Z-0004-2021Class IIOngoingVoluntary: Firm initiated
Z-0005-2021Class IIOngoingVoluntary: Firm initiated
Z-0006-2021Class IIOngoingVoluntary: Firm initiated
Z-0007-2021Class IIOngoingVoluntary: Firm initiated
Z-0008-2021Class IIOngoingVoluntary: Firm initiated
Z-0009-2021Class IIOngoingVoluntary: Firm initiated