CryoPatch SG Pulmonary Human Cardiac Patch. The patch is cryopreserved in a tissue culture medium containing...
CryoLife, Inc. began a recall of CryoPatch SG Pulmonary Human Cardiac Patch. The patch is cryopreserved in a tissue culture medium containing cryoprotectants within the innermost pouch of a... on . FDA classified it as Class II and gives the reason as "On November 10, 2020, it was discovered that there are post- processing microbial culture test failures for other allografts, processed using a TRIS saline solution lot that was also used in processing allografts...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0653-2021
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Artivion, Inc.
- Product
- CryoPatch SG Pulmonary Human Cardiac Patch. The patch is cryopreserved in a tissue culture medium containing cryoprotectants within the innermost pouch of a three-pouch packaging system. The packaging system not only withstands ultracold temperatures, but also allows for aseptic introduction of the patch into the operating environment. Supercooling by liquid nitrogen boost is begun prior to crystallization to minimize ice crystal damage to the patch matrix. Finally, the patch is transferred for long-term storage at or below 135 C. CryoPatch SG is distributed in three anatomic configurations: pulmonary hemi-artery, pulmonary trunk and pulmonary branch.
- Product code
- DXZ Patch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene
- Reason for recall
- On November 10, 2020, it was discovered that there are post- processing microbial culture test failures for other allografts, processed using a TRIS saline solution lot that was also used in processing allografts subjected to the recall.
- Root cause tag
- manufacturing process
- FDA root cause
- Material/Component Contamination
- Action
- A Recall notification letter titled "Urgent - Voluntary Human Tissue Recall" was sent to consignees via email or hand delivered by firm representatives. On 11-Nov-2020, 4 letters were delivered to consignees. On 12-Nov-2020, 2 letters were delivered to consignees. The letter instructs the consignee to complete and return the enclosed postcard affirming that they received the notification. The affected product should be quarantined and returned to CryoLife immediately, if it has not been implanted. CryoLife Field Representatives were to provide information necessary to arrange for the return of the affected product. If the product has been implanted and the consignee has questions or requires clarification, the consignee is to contact Dr. Gregory Ray, CryloLife Medical Director at 800-438-8285.
- Quantity in commerce
- 2 units
- Distribution
- Distributed nationwide to GA, AZ, TX, MO, and OK.
- Product codes and lots
- Model/Catalog Number: SGP020 Serial Numbers: 11677186, 11679112, and 11681763 UDI: 00877234000485
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0652-2021 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0653-2021 | Class II | Terminated | Voluntary: Firm initiated |