Z-0723-2021Class II
Vanguard 360 Revision System Posterior Augment With Bolt -
Zimmer GmbH / initiated 2020-12-01 / Terminated / root cause: manufacturing process
Biomet, Inc. began a recall of Vanguard 360 Revision System Posterior Augment With Bolt - Product Usage: intended for use in knee arthroplasty Item Number: 185422 on . FDA classified it as Class II and gives the reason as "Incorrect bolt -tibial bolts in package instead of femoral bolts may delay procedure". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0723-2021
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- Vanguard 360 Revision System Posterior Augment With Bolt - Product Usage: intended for use in knee arthroplasty Item Number: 185422
- Product code
- JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
- Reason for recall
- Incorrect bolt -tibial bolts in package instead of femoral bolts may delay procedure
- Root cause tag
- manufacturing process
- FDA root cause
- Process control
- Action
- .Zimmer Biomet issued Urgent Medical Device Recall letter issued on 12/1/20 to distributors with direct sales and/or fielded inventory via email and traceable letter sent via FedEx. Hospitals with direct sales or current inventory will be notified via FedEx. Letter states reason for recall , health risk and action to take: Distributors esponsibilities include: locating and removing the product in their territory, as well as identifying hospitals who have previously used the product. Review this notification and ensure that affected personnel are aware of the contents. 2. If you have affected product at your facility, assist your Zimmer Biomet sales representative and quarantine all affected product. Your Zimmer Biomet sales representative will remove the affected product from your facility. 3. If the product has been further distributed, provide your customers with the field safety notice for hospitals and ensure documentation. 4. Complete Attachment 1 Certificate of Acknowledgement and send to [email protected]. This form shall be returned even if you do not have affected products at your facility. 5. Retain a copy of the acknowledgement form with your recall records in the event of a compliance audit of your facilitys documentation. 6. If you have further questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of call center operating hours will receive a voicemail prompt or be transferred to an on-call representative in the event of an emergency. Alternatively, your questions may be emailed to [email protected].
- Quantity in commerce
- 21 units
- Distribution
- Worldwide distribution - US Nationwide distribution in the state of FL and the countries of Korea, Japan, Netherlands.
- Product codes and lots
- Lot Number: 098780 UDI Number: (01) 00880304482739 (17) 290501 (10) 098780
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0723-2021 | Class II | Terminated | Voluntary: Firm initiated |