Z-1392-2021Class II
ADVIA 2120i Refurb Single Aspirate (SMN 11314044) - US, automated hematology analyzer Software Versions 6.10...
Siemens Healthcare Diagnostics Inc. / initiated 2021-03-05 / Open, Classified / root cause: labeling and UDI
Siemens Healthcare Diagnostics, Inc. began a recall of ADVIA 2120i Refurb Single Aspirate (SMN 11314044) - US, automated hematology analyzer Software Versions 6.10 and 6.11 on . FDA classified it as Class II and gives the reason as "Potential Sample Identification (SID) Mismatch with14-Character Barcodes". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-1392-2021
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Siemens Healthcare Diagnostics Inc.
- Product
- ADVIA 2120i Refurb Single Aspirate (SMN 11314044) - US, automated hematology analyzer Software Versions 6.10 and 6.11
- Product code
- GKZ Counter, Differential Cell
- Reason for recall
- Potential Sample Identification (SID) Mismatch with14-Character Barcodes
- Root cause tag
- labeling and UDI
- FDA root cause
- Under Investigation by firm
- Action
- Siemens Healthcare Diagnostics issued Urgent Medical Device Correction (UMDC) letter HSW21-01.A.US to US customers on March 5, 2021 via FedEx overnight delivery. An Urgent Field Safety Notice (UFSN) HSW21-01.A.OUS was issued to all OUS Siemens sites with affected customers electronically for distribution and regional reporting to their local competent authorities. Letter states reason for recall, health risk and action to take: with your Medical Director. If you are using 14-character Sample Identification (SID) barcodes: o Ensure that the Barcode Encoding Selectivity feature is enabled. Open the Sample Identification screen to determine if the checkbox to turn the Barcode Encoded Selectivity is on o If Barcode Encoding Selectivity is disabled, please perform the following steps to enable Barcode Encoding Selectivity: Open the Sample Identification screen Select the checkbox to turn the Barcode Encoded Selectivity on Whether or not you have the Barcode Encode Selectivity feature disabled, please complete and return the Field Correction Effectiveness Check Form attached to this letter within 30 days. Please retain this letter with your laboratory records and forward this letter to those who may have received this product If you have any questions, please contact your Siemens Healthineers Customer Care Center or your local Siemens Healthineers technical support representative.
- Quantity in commerce
- 1 unit
- Distribution
- Worldwide distribution - US Nationwide distribution and the countries of Albania, Algeria, Angola, Argentina, Australia, Austria, Azerbaijan, Bahrain, Bangladesh, Belarus, Belgium, Benin, Bosnia Herzeg., Botswana, Brazil, Bulgaria, Burkina, Faso, Cambodia, Canada, Chile, Colombia, Croatia, Cura¿ao Cyprus, Czech Republic, Denmark, Ecuador, Egypt, Finland, France, Fren.Polynesia, Georgia, Germany, Greece, Guadeloupe, Hong Kong, Hungary, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Kenya, Kuwait, Lebanon, Lithuania, Luxembourg, Macedonia, Malaysia, Mali Malta, Martinique, Mexico, Namibia, Netherlands, Norway, Oman, P.R. China, Pakistan, Peru, Philippines, Poland, Portugal, Qatar, Rep. of Yemen, Republic Korea, Romania, Russian Fed., San Marino, Saudi Arabia, Senegal, Serbia, Singapore, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Syria, Taiwan, Thailand, Trinidad,Tobago, Turkey, Turkmenistan, U.A.E., Ukraine, United Kingdom, Uruguay, Vatikancity, Vietnam.
- Product codes and lots
- Software Versions 6.10 and 6.11 UDI: 00630414237879
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1386-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1387-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1388-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1389-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1390-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1391-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1392-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1393-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1394-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1395-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1396-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1397-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1398-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1399-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1400-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1401-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1402-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1403-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1404-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1405-2021 | Class II | Ongoing | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.