Z-1629-2021Class II

BiPAP A30, Brazil: Continuous ventilator, non-life-supporting. Material Number: BR1111143

Respironics, Inc. / initiated 2021-04-06 / Terminated / root cause: manufacturing process

Philips Respironics, Inc. began a recall of BiPAP A30, Brazil: Continuous ventilator, non-life-supporting. Material Number: BR1111143 on . FDA classified it as Class II and gives the reason as "Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-1629-2021
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Respironics, Inc.
Product
BiPAP A30, Brazil: Continuous ventilator, non-life-supporting. Material Number: BR1111143
Product code
MNS Ventilator, Continuous, Non-Life-Supporting
Reason for recall
Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxicological hazard and 2. Sudden failure of the device causing a Ventilator Inoperative condition with the potential for asphyxia if not immediately identified and addressed by the care provider.
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
In April, 2021, Philips issued an Urgent Medical Device Removal notice to customers via letter notifying them that Philips determined that certain devices were built with motor assemblies that could contain non-conforming plastic material. ACTION TO BE TAKEN BY CUSTOMER / USER 1. Locate all impacted devices listed above immediately STOP USE. All impacted devices must be removed from service. Replace with a non-impacted device if it is being used by a patient. 2. This notice needs to be passed on to all those who must be aware within your organization or to any organization where the impacted devices have been transferred. 3. Once impacted devices have been removed from service and isolated notify your Philips Representative that the impacted devices are ready for return. Your Philips Representative will arrange for return of the device. Replacements will be provided free of charge. 4. Fill out the Business Reply Form that has been provided with this letter and return it to your Philips Representative. This form serves as official acknowledgement that you have fully performed your obligations to complete this medical device recall.
Quantity in commerce
2 units
Distribution
Distribution US nationwide to states of: LA, PA, WI, CO, WV, WA, CA, TX, MO, OK, FL, and TN. Brazil, China, and Japan
Product codes and lots
Serial Number: N306151248079, N306164395E34

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1629-2021
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1625-2021Class IITerminatedVoluntary: Firm initiated
Z-1626-2021Class IITerminatedVoluntary: Firm initiated
Z-1627-2021Class IITerminatedVoluntary: Firm initiated
Z-1628-2021Class IITerminatedVoluntary: Firm initiated
Z-1629-2021Class IITerminatedVoluntary: Firm initiated
Z-1630-2021Class IITerminatedVoluntary: Firm initiated