BD SmartSite Bag Access Device Needle-Free Valve, REF: 2300E; BD Bag access Device with 1 Check Valve And...
CAREFUSION began a recall of BD SmartSite Bag Access Device Needle-Free Valve, REF: 2300E; BD Bag access Device with 1 Check Valve And Needle Free Valve, REF: 2309E-0006 on . FDA classified it as Class II and gives the reason as "Needle-free connector valves, either standalone or attached to extension sets, may have issues including difficulty to flush, flow issues, and partial or total occlusions, which could lead to therapy delay. Follow-up...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-2468-2021
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- CareFusion 303, Inc
- Product
- BD SmartSite Bag Access Device Needle-Free Valve, REF: 2300E; BD Bag access Device with 1 Check Valve And Needle Free Valve, REF: 2309E-0006
- Product code
- FPA Set, Administration, Intravascular
- Reason for recall
- Needle-free connector valves, either standalone or attached to extension sets, may have issues including difficulty to flush, flow issues, and partial or total occlusions, which could lead to therapy delay. Follow-up activates not required if product has already been used or was safely connected to the female luer of connecting device.
- Root cause tag
- manufacturing process
- FDA root cause
- Process control
- Action
- On 08/02/21, Urgent Medical Device Correction notices were mailed and emailed to consignees who were asked to notify recalling firm if this issue was experienced at 1-844-823-5433, [email protected] . Follow-up activates not required if product has already been used or was safely connected to the female luer of connecting device. If during priming the clinician encounters an occluded needle-free connector, take the following actions: 1) Depress the syringe plunger while the syringe is still attached to the needle-free connector. 2) If unable to depress the plunger, pull back on the syringe plunger and depress the syringe plunger again. Repeating this step may assist in opening the needle-free connector valve. 3) If the valve still is not open; without disconnecting the syringe male luer tip from the BD SmartSite valve surface, carefully unthread and rethread the syringe to partially disengage and reengage the syringe. Repeating this step up to three times may assist in opening the needle-free valve. Note: To maintain sterility, do not allow the syringe and needle-free valve to completely disconnect. 4) If previous steps do not open the valve, then open a new needle-free connector to replace the occluded connector. 5) After the steps above, proceed with the existing instructions for use. 6) Share this correction notification with all users within your facility network of the product to ensure they are also aware of this correction. 7) Complete and return the Customer Response Form. Distributors were asked to identify customers within their distribution network that purchased the affected product and to email an excel file listing of all customers to the recalling firm within 72 hours of receipt of this letter so the recalling firm can initiate customer notification. See online tool to support the identification of impacted lot numbers https://www.bd.com/MDS-21-4144
- Quantity in commerce
- 295,331
- Distribution
- Worldwide distribution - US Nationwide distribution in the states of FL, PA, NC, OH, SC, IL, RI, MO, NY, TN, AL, VA, PR, CA, NE, NJ, MI, MD, NM, LA, KY, NV, ME, OK, WA, MA, WV, TX, AR, OR, KS, GA, VT, IN, WY, AZ, CO, MN, WI, UT, SD, MS, ID, MT, ND, HI, IA, DC, AK, NH, CT, DE, GU and the countries of CA, NZ, TW, AU, BE, VN, AR, MY, TH, KR, ID, PH, SG, BH, SA, HK, IN, CN, BR.
- Product codes and lots
- Lots: 20066502 20066503 20066504 20076251 20076352 20086483 20086484 20086485 20086486 20087129 20087130 20096280 20096281 20096282 20096283 20097163 20105074 20105075 20095374 20095375 20096302 20105754 20105755 20105756 20105757 20105758 20115470 21036462 21036463 21036464 21036465 21036466
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2454-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2455-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2456-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2457-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2458-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2459-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2460-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2461-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2462-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2463-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2464-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2465-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2466-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2467-2021 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2468-2021 | Class II | Ongoing | Voluntary: Firm initiated |