Z-0136-2022Class II
Discovery MR750 3.0T nuclear magnetic resonance imaging system
GE Healthcare / initiated 2021-08-26 / Terminated / root cause: software
GE Healthcare, LLC began a recall of Discovery MR750 3.0T nuclear magnetic resonance imaging system on . FDA classified it as Class II and gives the reason as "Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images". As of , the recall status on record is Terminated, and MDM tags the root cause as software.
Recall record
- Recall number
- Z-0136-2022
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- GE Healthcare
- Product
- Discovery MR750 3.0T nuclear magnetic resonance imaging system
- Product code
- LNH System, Nuclear Magnetic Resonance Imaging
- Reason for recall
- Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images.
- Root cause tag
- software
- FDA root cause
- Software design
- Action
- GE issued an Urgent Medical Device Correction letter to customers with affected devices. This letter informs the customer of the issue and provides safety instructions for the continued use of the device. GE Healthcare will correct all affected devices at no cost to the customer. In the U.S., this letter will be sent by a traceable means. This letter will be sent to the following titles within the affected accounts: Director of Clinical/Radiology, Risk Manager/Hospital Administrator.
- Quantity in commerce
- 5 devices
- Distribution
- Distribution in United States to AZ, CA, FL, GA, IL, LA, MA, MD, MN, NC, NH, NJ, NY, OH, OK, TX, VA, WA, and Puerto Rico OUS distribution to: Australia, Belgium, Canada, Chile, Colombia, France, Germany, Italy, Japan, Korea, Poland, Saudi Arabia, Spain, Sweden, Turkey, UAE, and UK
- Product codes and lots
- Software version DV29.1
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0132-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0133-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0134-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0135-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0136-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0137-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0138-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0139-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0140-2022 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0141-2022 | Class II | Terminated | Voluntary: Firm initiated |