SHIP KIT, PROCEDURE KIT, PROTEKDUO LS - DL31 for temporary Cardiopulmonary bypass. Including the following...
Cardiac Assist, Inc began a recall of SHIP KIT, PROCEDURE KIT, PROTEKDUO LS - DL31 for temporary Cardiopulmonary bypass. Including the following components: a) 31 Fr ProtekDuo Veno-Venous Cannula... on . FDA classified it as Class III and gives the reason as "Top label of the outer package of the collection kit Item 5820-3118 showed expiration date of 2022/05/01 (correct expiration date) while side label showed expiration date of 2021/05/01 (incorrect expiration date)". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-0311-2022
- Classification
- Class III
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Cardiac Assist, Inc
- Product
- SHIP KIT, PROCEDURE KIT, PROTEKDUO LS - DL31 for temporary Cardiopulmonary bypass. Including the following components: a) 31 Fr ProtekDuo Veno-Venous Cannula Set b) LifeSPARC Pump c) 14Fr to 26 Fr Dilator Set d) TandemHeart Wrap. Kit Number: 5820-3118 Intended use is applicable to the intended use of specific devices included in the kit.
- Product code
- DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
- Reason for recall
- Top label of the outer package of the collection kit Item 5820-3118 showed expiration date of 2022/05/01 (correct expiration date) while side label showed expiration date of 2021/05/01 (incorrect expiration date)
- Root cause tag
- labeling and UDI
- FDA root cause
- Error in labeling
- Action
- LiNova issued an "URGENT MEDICAL DEVICE REMOVAL" letter (FA-CP-PIT-2021-003) dated October 13th, 2021 via e-mail on 14 October 2021. Letter states reason for recall, health risk and action to take: TandemLife recommends using the device as labelled and dispose the outer packaging. TandemLife kindly requests your execution of the following actions: 1. Using attached Response Form in Attachment 1 of this letter, please: - If you have already discarded of outer packaging prior to the receipt of this letter, please proceed to step 2 - Check your inventory for the presence of potentially affected kit contained within your ordered kit as per Table provided in Attachment 1; - Please dispose of the outer packaging of your impacted product upon notification of this letter. - Please use your devices as labelled on the device level labeling. 2. Return the attached Response Form in Attachment 1 by email to [email protected] to confirm appropriate corrective actions have been executed. Please return the Response Form even if each potentially affected device listed in Attachment 1 has already been used. For questions regarding this Medical Device Removal, please contact your TandemLife representative, or TandemLife Customer Quality at [email protected].
- Quantity in commerce
- 7 units
- Distribution
- US Distribution to states of: DC, MA, SC, and VA.
- Product codes and lots
- Serial Numbers: 872170, 872171, 872172, 872173, 872182, 872183, 872184. UDI: 01)00814112020791(17)220 501(22)220511(21) 872170; (01)00814112020791(17)220 501(22)220511(21) 872171; (01)00814112020791(17)220 501(22)220511(21) 872172; (01)00814112020791(17)220 501(22)220511(21) 872173; (01)00814112020791(17)220 501(22)220511(21) 872182; (01)00814112020791(17)220 501(22)220511(21) 872183; 01)00814112020791(17)220 501(22)220511(21) 872184
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0311-2022 | Class III | Ongoing | Voluntary: Firm initiated |