Philips Azurion systems with software releases 2.1(L1) and 2.1(L2)
Philips Healthcare began a recall of Philips Azurion systems with software releases 2.1(L1) and 2.1(L2) on . FDA classified it as Class II and gives the reason as "3D-RA is a reconstruction software product that can be used with the Philips Azurin system. This product extends the functionality of compatible X-ray equipment with the capability of 3D X-ray imaging. Before starting a...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as software.
Recall record
- Recall number
- Z-0238-2022
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Philips North America LLC
- Product
- Philips Azurion systems with software releases 2.1(L1) and 2.1(L2)
- Product code
- OWB Interventional Fluoroscopic X-Ray System
- Reason for recall
- 3D-RA is a reconstruction software product that can be used with the Philips Azurin system. This product extends the functionality of compatible X-ray equipment with the capability of 3D X-ray imaging. Before starting a 3D-RA scan, the detector of the Philips Azurion system must be positioned in portrait or landscape orientation with an angle of 0 or +/-90 degrees relative to the 3D scan direction. Philips has discovered that Azurion releases 2.1(L1) and 2.1(L2) allow creation of a 3D-RA scan with a deviating detector orientation of up to 3 degrees from the exact portrait or landscape orientation (i.e., at 0 or +/-90 degrees), relative to the 3D scan direction. 3D-RA scans with a deviating detector orientation of ore than 1.0 degree from the exact portrait or landscape orientation (i.e., at 0 or +/-90 degrees) cannot be reconstructed with the 3D-RA reconstruction software.
- Root cause tag
- software
- FDA root cause
- Radiation Control for Health and Safety Act
- Action
- Philips will inform customers of the issue via an Electronic Product Radiation Correction notification. The letter identified the affected product, problem and actions to be taken. Philips Field Service Engineers will schedule an appointment with customers to install the software update. For questions contact your Philips representative at 1-800-722-9377.
- Quantity in commerce
- 226 units
- Distribution
- US Nationwide distribution
- Product codes and lots
- Azurion 2.1(L1) and 2.1(L2)
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0238-2022 | Class II | Ongoing | FDA Mandated |