Z-0625-2022Class I

Arrow-Trerotola Over-The-Wire PTD Kit, Percutaneous Thrombolytic Device, REF PT-65709-W containing component...

Teleflex Medical / initiated 2022-01-11 / Terminated

TELEFLEX MEDICAL INC began a recall of Arrow-Trerotola Over-The-Wire PTD Kit, Percutaneous Thrombolytic Device, REF PT-65709-W containing component: PT-65709-C The Arrow-Trerotola Percutaneous... on . FDA classified it as Class I and gives the reason as "The firm received reports indicating PTD tip separation during use". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-0625-2022
Classification
Class I
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Teleflex Medical
Product
Arrow-Trerotola Over-The-Wire PTD Kit, Percutaneous Thrombolytic Device, REF PT-65709-W containing component: PT-65709-C The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venous (AV) fistulae and synthetic dialysis grafts.
Product code
QEW Peripheral Mechanical Thrombectomy With Aspiration
Reason for recall
The firm received reports indicating PTD tip separation during use.
FDA root cause
Process change control
Action
Arrow International LLC/Teleflex notified their consignees by letter on 01/11/2022. The letter explained the issue and requested that the consignee cease use and distribution. Distributors were directed to notify their customers. The firm is seeking return of the affected product. The following instructions were provided: Action list number 1 Medical facilities 1. We request that you check your inventory for product within the scope of this FSCA. Users should cease use and distribution of impacted product and quarantine immediately. 2. If you do not have stock in scope of this FSCA mark the according checkbox on the Acknowledgement Form (Appendix 1) and return the form to the fax number or e-mail address mentioned below. 3. If you do have stock in scope of this FSCA, complete the Acknowledgement Form (Appendix 1) and fax it to 1-855-419-8507, Attn: Customer Service or e-mail to [email protected]. This will allow us to document the amount of product you have on hand for return. A customer service representative will contact you with a Return Goods Authorization (RGA) Number and will provide instructions for the return of products to Teleflex Medical. Action list number 2 Distributors 1. Provide this field safety notice to all customers who have received product in scope of this FSCA. Your customer is then required to complete the Acknowledgement Form and return to you. 2. We request that you check your inventory for product within the scope of this FSCA. Cease use and distribution of impacted product and quarantine immediately. You may then return all product in scope to Teleflex. 3. As a distributor, you are then required to confirm to Teleflex that you have completed the field activity outlined above. Upon completion of your actions, please forward the completed Acknowledgement Form to Customer Service. Important - Please ensure you only list batch numbers in scope of this Field Safety Notice when completing this form. 4. If you have further distr
Quantity in commerce
1265 units
Distribution
Worldwide distribution: US Nationwide and the countries of AU, BE, CA, CL, CZ, DE, ES, FR, GB, IL, IT, KR, KW, NL, PA, PH, PT, SA, TR.
Product codes and lots
Lot Number / UDI: 13F19M0129 / (01)10801902121315 (17)211130 (10)13F19M0129, Components: Code PT-65709-C, Lot number 13C19M0499; Lot Number / UDI: 13F20B0053 / (01)108019022121315 (17)220131 (10)13F20B0053, Components: Code PT-65709-C, Lot number 13C20A0970; Lot Number / UDI: 13F20C0595 / (01)10801902121315 (17)220331 (10)13F20C0595, Components: Code PT-65709-C, Lot number 13C20C2089; Code PT-65709-C, Lot number 13C20C2082; Lot Number / UDI: 13F20F0231 / (01)10801902121315 (17)220531 (10)13F20F0231, Components: Code PT-65709-C, Lot number 13C20F1139; Lot Number / UDI: 13F20G0361 / (01)10801902121315 (17)220731 (10)13F20G0361, Components: Code PT-65709-C, Lot number 13C20G1199; Code PT-65709-C, Lot number 13C20G0228; Lot Number / UDI: 13F20K0632 / (01)10801902121315 (17)221031 (10)13F20K0632, Components: Code PT-65709-C, Lot number 13C20H1675; Lot Number / UDI: 13F21A0353 / (01)10801902121315 (17)221231 (10)13F21A0353, Components: Code PT-65709-C, Lot number 13C20M0639; Code PT-65709-C, Lot number 13C20J2689; Lot Number / UDI: 13F21C0748 / (01)10801902121315 (17)230331 (10)13F21C0748, Components: Code PT-65709-C, Lot number 13C21C1696; Lot Number / UDI: 13F21D0721 / (01)10801902121315 (17)230430 (10)13F21D0721, Components: Code PT-65709-C, Lot number 13C21C1696; Code PT-65709-C, Lot number 13C21C2412; Code PT-65709-C, Lot number 13C21C0326; Lot Number / UDI: 13F21E0823 / (01)10801902121315 (17)230531 (10)13F21E0823, Components: Code PT-65709-C, Lot number 13C21E0328; Lot Number / UDI: 13F21F1189 / (01)10801902121315 (17)230630 (01)13F21F1189, Components: Code PT-65709-C, Lot number 13C21E1991; Code PT-65709-C, Lot number 13C21E0328

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0625-2022
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0623-2022Class ITerminatedVoluntary: Firm initiated
Z-0624-2022Class ITerminatedVoluntary: Firm initiated
Z-0625-2022Class ITerminatedVoluntary: Firm initiated
Z-0626-2022Class ITerminatedVoluntary: Firm initiated
Z-0627-2022Class ITerminatedVoluntary: Firm initiated
Z-0628-2022Class ITerminatedVoluntary: Firm initiated
Z-0629-2022Class ITerminatedVoluntary: Firm initiated