Z-1206-2022Class II

The C304-HIS device features a guide wire to access the vein, a valve to reduce blood loss during the implant...

Medtronic, Inc. / initiated 2022-04-20 / Open, Classified / root cause: sterility

Medtronic Inc., Cardiac Rhythm and Heart Failure (CRHF) began a recall of The C304-HIS device features a guide wire to access the vein, a valve to reduce blood loss during the implant procedure, a deflectable catheter to introduce a... on . FDA classified it as Class II and gives the reason as "The firm's internal processes identified that certain lots may have an improperly sealed barrier that could potentially compromise sterility". As of , the recall status on record is Open, Classified, and MDM tags the root cause as sterility.

Recall record

Recall number
Z-1206-2022
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Medtronic, Inc.
Product
The C304-HIS device features a guide wire to access the vein, a valve to reduce blood loss during the implant procedure, a deflectable catheter to introduce a transvenous device, a catheter dilator to facilitate deflectable catheter passage, and a guide catheter slitter to remove the deflectable catheter. The deflectable catheter is designed for placement of transvenous devices in or near the bundle of His. It features a deflecting distal section, controlled by the deflectable catheter handle, and an out-of plane curve on the distal tip. The body of the deflectable catheter is radiopaque for visibility on fluoroscopy.
Product code
DQY Catheter, Percutaneous
Reason for recall
The firm's internal processes identified that certain lots may have an improperly sealed barrier that could potentially compromise sterility.
Root cause tag
sterility
FDA root cause
Under Investigation by firm
Action
The firm sent out a recall notification starting on 04/20/2022 via UPS 2-day delivery. Customers are asked to return all unused affected product, share the notice with all those who need to be aware within their organization or with any organization where the above-listed products have been transferred, and to complete the response form.
Quantity in commerce
1385 devices
Distribution
Worldwide distribution - US Nationwide distribution in the states of AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, NC, NE, NH, NJ, NY, OH, OR, PA, SC, TN, TX, UT, VA, VT, WA, WI, WV and the countries of Belgium, Denmark, France, Germany, Ireland, Italy, Netherlands, Poland, Spain, United Arab Emirates, United Kingdom.
Product codes and lots
Model Number: C304-HIS; GTIN: 00763000147013; Lot Numbers: 0010948864, 0010953298, 0010958150, 0010961222, 0010971148, 0011017539, 0011020263, 0011022874, 0011025202, 0011028574, 0011031177

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1206-2022
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1206-2022Class IIOngoingVoluntary: Firm initiated