Z-1370-2022Class II

NATURALYTE Liquid Acid 2.0K 2.5Ca- indicated for use in patients undergoing extracorporeal bicarbonate...

Fresenius Medical Care Renal Therapies Group, LLC / initiated 2022-05-31 / Open, Classified / root cause: labeling and UDI

Fresenius Medical Care Holdings, Inc. began a recall of NATURALYTE Liquid Acid 2.0K 2.5Ca- indicated for use in patients undergoing extracorporeal bicarbonate hemodialysis for acute and chronic renal failure Part... on . FDA classified it as Class II and gives the reason as "Alternate Bottle Caps labeled with "Sealed for your Protection" on the foil not qualified for use". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-1370-2022
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Fresenius Medical Care Renal Therapies Group, LLC
Product
NATURALYTE Liquid Acid 2.0K 2.5Ca- indicated for use in patients undergoing extracorporeal bicarbonate hemodialysis for acute and chronic renal failure Part Number: 08-2251-0
Product code
KPO Dialysate Concentrate For Hemodialysis (Liquid Or Powder)
Reason for recall
Alternate Bottle Caps labeled with "Sealed for your Protection" on the foil not qualified for use
Root cause tag
labeling and UDI
FDA root cause
Under Investigation by firm
Action
Fresenius Medical Care issued Urgent Medical Device Recall letter (FA-2022-11-T) dated 6/2/22. Letter states reason for recall, health risk and action to take: These instructions apply only to clinics directly contacted by the Fresenius Medical Care Corrections and Removals Department. " Immediately examine your stock to determine whether you have NaturaLyte Liquid Acid concentrate with the part and lot numbers listed below. " Only bottles with sealed for your protection on the bottle cap foil are affected (see picture below). " Remove the affected product from your inventory. " FMCRTG, LLC will contact you regarding product return. Please contact FMCRTG Customer Service at 1-800-323-5188 if you have any further questions.
Quantity in commerce
656 cases
Distribution
Natiowide
Product codes and lots
UDI-DI: (01) 000840861101696  (17) 240331  (10) 22CTAC106  Lot Number: 22CTAC106 Exp Date: 2024-03-31

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1370-2022
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1370-2022Class IIOngoingVoluntary: Firm initiated
Z-1371-2022Class IIOngoingVoluntary: Firm initiated