Z-1569-2023Class II

Aesculap Caiman Articulating D5/360MM - An electrosurgical cutting and coagulation device for...

Aesculap Inc / initiated 2023-03-21 / Open, Classified / root cause: design

Aesculap Implant Systems LLC began a recall of Aesculap Caiman Articulating D5/360MM - An electrosurgical cutting and coagulation device for cutting/coagulation/ablation during endoscopic (including... on . FDA classified it as Class II and gives the reason as "Potential for the spring to become loose and fall out of the device, if the spring falls out during a surgical procedure, it may enter the patient's body". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.

Recall record

Recall number
Z-1569-2023
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Aesculap Inc
Product
Aesculap Caiman Articulating D5/360MM - An electrosurgical cutting and coagulation device for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery, and may in addition be intended for open surgery. Product Code: PL771SU
Product code
GEI Electrosurgical, Cutting & Coagulation & Accessories
Reason for recall
Potential for the spring to become loose and fall out of the device, if the spring falls out during a surgical procedure, it may enter the patient's body.
Root cause tag
design
FDA root cause
Device Design
Action
Aesculap Inc. issued via Urgent Medical Device Recall Notification Letter via U.S Postal Service, Certified Mail Return Receipt Requested/ USPS Priority Mail on 3/21/23. Letter states reason for recall, health risk and action to take: Review the Device Recall Notification in its entirety and ensure that all users in your organization of the above-mentioned product, and other concerned persons, are informed about this voluntary product recall. If you are a distributor, please forward this recall notification to your customers. The recall is to be extended to the end user/customer level. 2. Determine your current inventory of the affected lots within your facility, cease use and quarantine product subject to recall. Do not destroy any affected product. 3. Utilizing the attached Product Recall Acknowledgement Form, record the total number of individual units in your possession. If you have no inventory remaining, please enter zero (0) on the form. 4. Return the completed Product Recall Acknowledgment Form form to the B. Braun Medical Inc. Quality Assurance department by faxing the form to (610) 849-1197 or e-mail to [email protected] within two (2) weeks of receipt, even if the total inventory in your possession is zero (0). 5. Once we receive your Acknowledgement Form, an Aesculap Customer Support representative will contact you to arrange for credit and to have your current inventory returned. Should you identify a problem or safety concern with the product, please report the event promptly by contacting our Postmarket Surveillance Department at 1-833-425-1464.
Quantity in commerce
6 pieces
Distribution
US Nationwide distribution in the state of OH.
Product codes and lots
UDI-DI: 04046964837340 Lot Number: 52785146

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1569-2023
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1569-2023Class IIOngoingVoluntary: Firm initiated