Z-2265-2023Class II

Always-On Tip Tracked Instruments (SPiN Drive instruments) 19ga ANSO Histology Needle, 12mm L, 1.8mm...

OLYMPUS Corporation of the Americas / initiated 2023-05-15 / Open, Classified / root cause: design

Olympus Corporation of the Americas began a recall of Always-On Tip Tracked Instruments (SPiN Drive instruments) 19ga ANSO Histology Needle, 12mm L, 1.8mm OD-Intended for use in clinical interventions and for... on . FDA classified it as Class II and gives the reason as "Electromagnetic (EM) sensor tracking malfunction impacts the use of navigation functionality during endobronchial procedures and prompts the system to report a coil break warning message. This could result in a...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.

Recall record

Recall number
Z-2265-2023
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
OLYMPUS Corporation of the Americas
Product
Always-On Tip Tracked Instruments (SPiN Drive instruments) 19ga ANSO Histology Needle, 12mm L, 1.8mm OD-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing Model: INS-0382
Product code
JAK System, X-Ray, Tomography, Computed
Reason for recall
Electromagnetic (EM) sensor tracking malfunction impacts the use of navigation functionality during endobronchial procedures and prompts the system to report a coil break warning message. This could result in a potential procedural delay
Root cause tag
design
FDA root cause
Component design/selection
Action
Olympus issued "URGENT - Medical Device Field Corrective Action" on 5/15/23. Letter states reason for recall, health risk and action to take: Olympus implemented a new internal component and has observed a reduction in complaints for the above-mentioned issue. However, to minimize the duration of potential procedure delay, Olympus is revising the Instruction for Use to add the below precaution statement: It is required to have additional Always-On Tip Tracked instruments available for all procedures as tracking may be lost when: Connecting the instrument to the SPiN Thoracic Navigation System Inserting and withdrawing the instrument from the working channel of the bronchoscope during procedure Navigating and sampling in tortuous patient anatomy Action steps to be taken by the end user: Our records indicate that you have purchased one or more of the affected products. Olympus requires you to take the following action: 1. Notify and ensure your users are knowledgeable about this additional precaution requiring additional instruments be available for all procedures. 2. Olympus requests that you acknowledge receipt of this letter by accessing the Olympus recall portal. a) Go to https://olympusamerica.com/recall. b) Enter the recall number 0425 c) Complete the form as instructed. 3. If you have distributed these devices outside your facility, please notify your customers of this matter immediately. Your notification to your customers may be enhanced by including a copy of this letter. Olympus requests that you report complaints associated with the use of this device, including patient injuries and adverse events, to our Technical Assistance Center (TAC) at 1-800-848-9024 (option 1 to report complaints). Contact (647) 999-3203 or at [email protected] for any additional information or support concerning this matter.
Quantity in commerce
526.4 units
Distribution
Worldwide Distribution: US (Nationwide) and OUS (foreign) to countries of: CN, DE, HK, IT, KR, SG, TH & TW.
Product codes and lots
UDI-DI: 00815686020590 Lot Numbers: 04992210324 and below

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2265-2023
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2262-2023Class IIOngoingVoluntary: Firm initiated
Z-2263-2023Class IIOngoingVoluntary: Firm initiated
Z-2264-2023Class IIOngoingVoluntary: Firm initiated
Z-2265-2023Class IIOngoingVoluntary: Firm initiated
Z-2266-2023Class IIOngoingVoluntary: Firm initiated
Z-2267-2023Class IIOngoingVoluntary: Firm initiated
Z-2268-2023Class IIOngoingVoluntary: Firm initiated
Z-2269-2023Class IIOngoingVoluntary: Firm initiated