Z-0439-2024Class II
CardioQuip Modular Cooler-Heater, Model:MCH-1000(i), Power: 115V-60hz,16A
CardioQuip / initiated 2023-10-19 / Open, Classified / root cause: design
CardioQuip, LLC began a recall of CardioQuip Modular Cooler-Heater, Model:MCH-1000(i), Power: 115V-60hz,16A on . FDA classified it as Class II and gives the reason as "There is a potential for the heating-chamber to malfunction resulting in melting/burning of the heater chamber components". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0439-2024
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- CardioQuip
- Product
- CardioQuip Modular Cooler-Heater, Model:MCH-1000(i), Power: 115V-60hz,16A
- Product code
- DWC Controller, Temperature, Cardiopulmonary Bypass
- Reason for recall
- There is a potential for the heating-chamber to malfunction resulting in melting/burning of the heater chamber components.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- On 10/19/23, CardioQuip issued a "Urgent: Medical Device Correction" notification to all affected consignees. This notification was an update to the firm's May 22, 2023 communication. CardioQuip ask consignees to take the following actions: 1. Prime the MCH-1000(i) and MCH-1000(m) prior to each use. 2.Never operate the device dry (see communication for further details). 3. Design Changes to be implemented (see communication for further details). A. Relocation of the water Level Sensor (see communication for further details). B. Software Update (see communication for further details). 4. Please fill out and submit the receipt of understanding of the contents of this letter to CardioQuip within 5 business days or receipt. 5. Any adverse events experienced relating to CardioQuip devices should be reported to CardioQuip or through the FDA s MedWatch Program: Phone: +1 (800) FDA-1088 Web: www.fda.gov/medwatch/report.htm
- Quantity in commerce
- 125 units
- Distribution
- US Distribution: TX, IN, IL, WI, FL, NJ, PA, KY, VA, WV, CT, CA, WA, AL, IA
- Product codes and lots
- UDI: (01)00860000846103/ Serial Numbers: Serial Numbers: 10160461, 10160463, 10160465, 10160466, 101060467, 10160468, 10161406, 10161408, 10161553, 10161689, 10160275 1016276, 1016277, 10160274, 10161065, 10161066, 10160825, 10160826, 10160827, 10160828, 10161140, 10161141, 10160830, 10160831, 10160832, 10160833, 10161543, 10160449, 10160450, 10160451, 10160452 , 1016050512, 10160513, 10160781, 10160785, 10160786, 10160787, 10160788, 10160789, 10160790, 10160791, 10160792, 10160793, 10160794, 10160795, 10161130, 10161131, 10161329, 10161517, 10160758, 10160094, 10160095, 10160096, 10160110, 10160113, 10160114, 10161294, 10161301, 10161303, 10161304, 10161306, 10160570, 10160572, 10160623 ,10160797, 10160798, 10160279, 10160280, 10160281, 10160282, 10161021, 10160797, 10161199, 10161200, 10161275, 10161343, 10161344, 10161560, 10161561, 10160824, 10160767, 10160097, 10160098, 10160099, 10160104, 10160105, 10160106, 10160108, 10160109, 10161043, 10161187, 10161679, 10161680, 10161681, 10160983, 10161830, 10160517, 10160519, 10160520, 10161312, 10160190, 10160191, 10160192, 10160193, 10160194, 10160248, 10160249, 10160250, 10160251, 10160967, 10160683, 10160684, 10160685, 10160686, 10160687, 10160688, 10160689, 10160690, 10161358, 10161359, 10161362, 10160084, 10160161, 10160183, 10161841
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0438-2024 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-0439-2024 | Class II | Ongoing | Voluntary: Firm initiated |