Vasoview Hemopro Endoscopic Vessel Harvesting System, model VH-3500
Maquet Cardiovascular, LLC began a recall of Vasoview Hemopro Endoscopic Vessel Harvesting System, model VH-3500 on . FDA classified it as Class II and gives the reason as "Risk of polyimide particulate matter being present on the endoscopic harvesting vessel system. This issue may result in polyimide particulate matter being introduced into the arterial conduit for patients undergoing a...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0724-2024
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Maquet Cardiovascular LLC
- Product
- Vasoview Hemopro Endoscopic Vessel Harvesting System, model VH-3500.
- Product code
- GEI Electrosurgical, Cutting & Coagulation & Accessories
- Reason for recall
- Risk of polyimide particulate matter being present on the endoscopic harvesting vessel system. This issue may result in polyimide particulate matter being introduced into the arterial conduit for patients undergoing a coronary artery bypass graft (CABG) or peripheral bypass graft surgery.
- Root cause tag
- design
- FDA root cause
- Component design/selection
- Action
- An Urgent Medical Device Correction notice dated December 1, 2023 was sent via FedEx 2-Day delivery. Please examine your inventory immediately to determine if you have any of the product codes and lot numbers listed in the notice and remove these from use. Return any unused/unexpired affected product to Maquet/Getinge. Please forward this information to all current and potential VasoView HemoPro EVH System users within your hospital / facility. If you are a distributor who has shipped any affected products to customers, please forward this document to their attention for appropriate action. If you have any questions, please contact your Maquet/Getinge representative or call the Maquet/Getinge Customer Support at 888-880-2874, Monday through Friday, between the hours of 6 AM to 5 PM (Pacific Standard Time). Whether or not your facility has affected product listed in the notice, please complete and sign the MEDICAL DEVICE REMOVAL - RESPONSE FORM to acknowledge that you have received the notification. Return the completed form to Maquet/Getinge by e-mailing a scanned copy to [email protected] or by faxing the form to 1-800-878-9105.
- Quantity in commerce
- 38,094 units (US)
- Distribution
- US: OUS: China, Brazil, Hong Kong.
- Product codes and lots
- UDI-DI: 00607567701250, Lots: 3000279266, 3000280189, 3000281082, 3000281083, 3000281381, 3000282927, 3000283156, 3000281741, 3000286706, 3000287254, 3000288363, 3000288576, 3000289020, 3000289548, 3000289927, 3000290482, 3000291429, 3000291157, 3000291645, 3000292098, 3000293522, 3000293788, 3000293823, 3000295050, 3000294365, 3000295346, 3000296172, 3000296021, 3000296498, 3000297028, 3000300016, 3000299854, 3000300155, 3000300260, 3000301042, 3000301666, 3000302760, 3000303282, 3000303854, 3000304912, 3000304645, 3000306277, 3000306437, 3000307090, 3000307871, 3000308725, 3000310691, 3000311127, 3000311525, 3000311892, 3000312494, 3000312722, 3000314373, 3000314821, 3000316023, 3000316027, 3000316024, 3000317576, 3000317501, 3000317575, 3000318901, 3000318302, 3000320140, 3000320141, 3000320773, 3000320773, 3000321483, 3000321723, 3000323214, 3000324409, 3000324397, 3000325013, 3000325249, 3000325689, 3000325776, 3000328206, 3000328561, 3000329723, 3000328562, 3000330445, 3000331131, 3000331388, 3000332428, 3000332510, 3000332993, 3000333524, 3000333829, 3000334315, 3000335670, 3000336708, 3000337272, 3000339701, 3000340534, 3000341675, 3000341133, 3000342250, 3000342251, 3000343266, 3000343264, 3000344887, & 3000351187.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0723-2024 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-0724-2024 | Class II | Ongoing | Voluntary: Firm initiated |