Z-1512-2024Class I

Drger Perseus A500 Anesthesia Workstation

Draeger, Inc. / initiated 2024-03-20 / Open, Classified / root cause: labeling and UDI

Draeger Medical, Inc. began a recall of Drger Perseus A500 Anesthesia Workstation on . FDA classified it as Class I and gives the reason as "Unexpected shutdown while operating on battery power". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-1512-2024
Classification
Class I
Status
Open, Classified
Initiated
Posted
Recalling firm
Draeger, Inc.
Product
Drger Perseus A500 Anesthesia Workstation
Product code
BSZ Gas-Machine, Anesthesia
Reason for recall
Unexpected shutdown while operating on battery power.
Root cause tag
labeling and UDI
FDA root cause
Labeling design
Action
Consignees were sent an Urgent Medical Device Recall notification by mail on 3/20/24. The notice informs consignees of the possibility of device shutdown with possible loss of ventilation, which consignees are instructed to either use an emergency ventilation bag or apply manual ventilation with the Perseus with the provided instructions. Consignees are to perform a battery test on all affected devices in their inventory per the provided instructions in the recall notification. If the tested unit(s) fails the battery test, consignees are to contact Drager Service Technical Support between 8:00 AM and 8:00 PM at 1-800-437-2437 (option 2, option 2, option 2) to arrange replacement of the device's battery. Consignees are also instructed to avoid short discharging/charging cycles of devices; if this cannot be accommodated device batteries are to be tested every three months. A supplemental IFU has been released to include the additional maintenance instructions outlined in the recall notification and can be requested from the firm. Consignees with any questions can contact Michael Kelhart between 8:00 AM to 4:30 PM EST at 267-664-1131 or [email protected].
Quantity in commerce
16,841 units
Distribution
Domestic: Nationwide Distribution; Foreign: Angola, Argentina, Australia, Austria, Bahrain, Belarus, Belgium, Bolivia, Botswana, Brazil, Brunei Dar-se- S, Bulgaria, Canada, Chili, China, Columbia, Costa Rica, Croatia, Czech Republic, Denmark, Ecuador, Egypt, Finland, France, French Polynesia, French Guiana, Georgia, Germany, Gibraltar, Greece, Guadeloupe, Hungary, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Kenya, Kuwait, Lebanon, Liechtenstein, Lithuania, Malaysia, Maldives, Mauritius, Mayotte, Mexico, Morocco, Netherlands, New Zealand, Norway, Oman, Pakistan, Panama, Peru, Philippines, Poland, Portugal, Qatar, Reunion, Romania, Russian Federation, Saudi Arabia, Serbia, Singapore, Slovenia, Slovakia, South Africa, South Korea, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, Turkmenistan, Uganda, Ukraine, United Kingdom, Uruguay, United Arab Emirates, Vietnam.
Product codes and lots
Material No. MX06000; UDI-DI: 04048675253600; All Serial No.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1512-2024
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1512-2024Class IOngoingVoluntary: Firm initiated