Yamaha Surface Mounter YR series, YS series, i-Pulse series, Sigma series, S series, M series. Affected...
YAMAHA MOTOR CORPORATION began a recall of Yamaha Surface Mounter YR series, YS series, i-Pulse series, Sigma series, S series, M series. Affected models: YSM10, YSM20R(SV)-1, YSM20R(SV)-2, YSM20R-1... on . FDA classified it as Class II and gives the reason as "Non-medical laser products which were determined to not be in compliance with 21 C.F.R. 1010.2 in that they currently do not bear the required certification label". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-1815-2024
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Yamaha Motor Co Ltd
- Product
- Yamaha Surface Mounter YR series, YS series, i-Pulse series, Sigma series, S series, M series. Affected models: YSM10, YSM20R(SV)-1, YSM20R(SV)-2, YSM20R-1, YSM20R-2, YSM20-1, YSM20-2, YSM20W-2, YRM20-1, YRM20-2, SIGMA-G5S2, S20, M20 ***Updated as of 6/10/2024*** Surface Mounter model S10, YC8. Component Dispenser model YSD
- Product code
- RGA Product Incorporating Certified Class 1 Data Utility/Peripheral Laser Product
- Reason for recall
- Non-medical laser products which were determined to not be in compliance with 21 C.F.R. 1010.2 in that they currently do not bear the required certification label.
- Root cause tag
- labeling and UDI
- FDA root cause
- Radiation Control for Health and Safety Act
- Action
- Yamaha Motor Robotics has recently discovered that certain products may be out of compliance with FDA electronic product regulations in that they did not bear a required label at the time they were shipped. Our records indicate that you have received one or more of the products affected by this problem. In this packet, we are providing you with the missing labels and instructions on their placement to correct this matter. These actions are being taken at no expense to you. Corrective Action Instructions: 1. Please locate the certification labels provided in this packet. (If you need more, please contact the Corrective Action Plan Coordinator at [email protected] or (770) 420-5825 and we will send you more at no expense to you). 2. Following the label placement instructions for your product found below, affix the label in the indicated position. 3. Download the revised user manuals from the "YAMAHA Surface Mounter Support & Service" website (https://www.yamaha-smtservice.net/en/).
- Quantity in commerce
- 376
- Distribution
- US Nationwide
- Product codes and lots
- YR series Model YRM20-1, YRM20-2 YS series Model YC8, YSM10 YSM20-1, YSM20-2, YSM20W-2 YSM20R-1, YSM20R-2, YSM20R(SV)-1, YSM20R(SV)-2 i-PULSE series Model S10, S20, M20 Sigma series Model SIGMA-G5S2
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1815-2024 | Class II | Ongoing | FDA Mandated | ||
| Z-1816-2024 | Class II | Ongoing | FDA Mandated |
FIRST ARTICLE / WEEKLY