Z-0083-2025Class I

Aisys CS2 with Et Control. This anesthesia gas machine is intended to provide general inhalation anesthesia...

GE Healthcare / initiated 2024-07-12 / Open, Classified / root cause: design

Datex-Ohmeda, Inc. began a recall of Aisys CS2 with Et Control. This anesthesia gas machine is intended to provide general inhalation anesthesia and ventilatory support to patients and are to be... on . FDA classified it as Class I and gives the reason as "Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet (ACGO) port". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.

Recall record

Recall number
Z-0083-2025
Classification
Class I
Status
Open, Classified
Initiated
Posted
Recalling firm
GE Healthcare
Product
Aisys CS2 with Et Control. This anesthesia gas machine is intended to provide general inhalation anesthesia and ventilatory support to patients and are to be used only by medical professionals trained and qualified in the administration of general anesthesia.
Product code
QSF Software Option For Anesthesia Gas Machine To Achieve And Maintain Targeted End Tidal Oxygen And Anesthetic Agents
Reason for recall
Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet (ACGO) port.
Root cause tag
design
FDA root cause
Device Design
Action
GE Healthcare notified consignees on about 07/12/2024 via letter. Consignees were instructed to ensure all potential users complete the Preoperative Checkout procedure in its entirety, as detailed in the URM, make sure that the breathing circuit is correctly connected, only connect an auxiliary manual breathing circuit to the ACGO port, place the included addendum with the URM and inspect all potentially affected devices for the presence of covers applied to the ACGO Port and ACGO Switch. Additionally, customers were requested to complete and return the response form.
Quantity in commerce
92 units
Distribution
Worldwide distribution - US Nationwide and the countries of Aland Islands, ALBANIA, Algeria, Argentina, Australia, Austria, Azerbaijan, BAHAMAS, Bahrain, Bangladesh, BARBADOS, BELARUS, Belgium, Benin, Bermuda, Bolivia, BONAIRE, Bosnia and Herzegovina, Brazil, Brunei, Bulgaria, Cambodia, Cameroon, Canada, Chile, CHINA, Colombia, Costa Rica, Croatia, Curacao, Cyprus, Czech Republic, Denmark, Dominican Republic, Ecuador, Egypt, El Salvador, Estonia, ETHIOPIA, Falkland Islands, Finland, France, French Polynesia, Gabon, Georgia, Germany, Ghana, Gilbrator, Greece, Guadeloupe, Guatemala, Guyana, Honduras, Hong Kong, Hungary, ICELAND, India, Indonesia, Iran, IRAQ, Ireland, Israel, Italy, Jamaica, JAPAN, Jordan, Kazakhstan, KENYA, Korea (Republic Of), Korea, Republic of, Kuwait, Laos, LATVIA, Lebanon, Libya, LITHUANIA, Macedonia, Malaysia, Maldives, Malta, MAURITIUS, Mexico, Moldova, Montenegro, Morocco, Myanmar, Namibia, Nepal, Netherlands, New Zealand, Nicaragua, Nigeria, North Macedonia, Norway, Oman, PAKISTAN, Palestine, State of, Panama, Paraguay, Peru, Philippines, Poland, Portugal, PUERTO RICO, Qatar, REUNION, ROMANIA, Russia, San Marino, Saudi Arabia, Senegal, Serbia, SINGAPORE, Slovakia, Slovenia, South Africa, Spain, Sudan, Sweden, Switzerland, Syria, Taiwan, Tanzania, THAILAND, Trinidad and Tobago, Tunisia, Turkey, T¿rkiye, Uganda, UKRAINE, United Arab Emirates, United Kingdom, Uruguay, UZBEKISTAN, Venezuela, Vietnam, Yemen.
Product codes and lots
GTIN: 00195278588128. Model Number: 1011-9055-000. All Serial Numbers. Not model or lot specific. All devices of the indicated products configured with the AGCO option are potentially affected.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0083-2025
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0074-2025Class IOngoingVoluntary: Firm initiated
Z-0075-2025Class IOngoingVoluntary: Firm initiated
Z-0076-2025Class IOngoingVoluntary: Firm initiated
Z-0077-2025Class IOngoingVoluntary: Firm initiated
Z-0078-2025Class IOngoingVoluntary: Firm initiated
Z-0079-2025Class IOngoingVoluntary: Firm initiated
Z-0080-2025Class IOngoingVoluntary: Firm initiated
Z-0081-2025Class IOngoingVoluntary: Firm initiated
Z-0082-2025Class IOngoingVoluntary: Firm initiated
Z-0083-2025Class IOngoingVoluntary: Firm initiated
Z-0084-2025Class IOngoingVoluntary: Firm initiated