Abbott Navitor Titan, Vision Technology, Transcatheter Aortic Heart Valve, 35 mm, NVRO-35, Sterile
Abbott Medical began a recall of Abbott Navitor Titan, Vision Technology, Transcatheter Aortic Heart Valve, 35 mm, NVRO-35, Sterile on . FDA classified it as Class II and gives the reason as "A manufacturing error resulting in acceptance of valves with a leaflet deflection value that was outside of established specifications. This could potentially affect long-term durability of the impacted valve and/or...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0491-2025
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Abbott Medical
- Product
- Abbott Navitor Titan, Vision Technology, Transcatheter Aortic Heart Valve, 35 mm, NVRO-35, Sterile
- Product code
- NPT Aortic Valve, Prosthesis, Percutaneously Delivered
- Reason for recall
- A manufacturing error resulting in acceptance of valves with a leaflet deflection value that was outside of established specifications. This could potentially affect long-term durability of the impacted valve and/or cause potential valve failure.
- Root cause tag
- manufacturing process
- FDA root cause
- Under Investigation by firm
- Action
- A Medical Device Recall letter was hand delivered Oct. 21, 2024 to the one US consignee for 1 Impacted Valve. Nine foreign consignees were also notified for 26 Impacted Valves distributed outside of the United States (OUS). Customers are advised to return any remaining unused Impacted Valves, if applicable, and complete and return the accompanying Acknowledgement Form to Abbott. Abbott is executing further testing to verify that long-term durability of the Impacted Valves has not been affected and will communicate any changes to the recommendations set forth in this letter if needed by Q4 2025. In the interim, Abbott recommends continuing the same local standard of care in patients implanted with the Impacted Valve as would be used with patients implanted with any other transcatheter aortic valve implant. If you have any questions, please contact your local Sales Representative or Abbott Support at 1-800-544-1664 (Option 2).
- Quantity in commerce
- 1 US, 9 OUS
- Distribution
- New York, Australia, Belgium, Germany, Iran, Israel, Japan, Kazakhstan, Oman, Poland, Romania, Slovakia, Spain, Turkey, United Kingdom.
- Product codes and lots
- UDI-DI (GTIN): 05415067045768, Serial Numbers: 20078589, 20357219, 20357226, 20357685, 20358319, 20358343, 20358351, 20358363, 20358368, & 20358370.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0491-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-0492-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-0493-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-0494-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-0495-2025 | Class II | Ongoing | Voluntary: Firm initiated |