Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mm,35...

OLYMPUS Corporation of the Americas / initiated 2024-11-25 / Open, Classified

Olympus Corporation of the Americas began a recall of Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mm,35 cm, Front-actuated Grip Type S Model Number... on . FDA classified it as Class II and gives the reason as "The probe tips of the hand instruments are being damaged or breaking including pad damage and detachment". As of , the recall status on record is Open, Classified.

Recall record

Recall number
Z-0996-2025
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
OLYMPUS Corporation of the Americas
Product
Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mm,35 cm, Front-actuated Grip Type S Model Number: TB-0535FCS Catalog Number/Product Code: N5423730 Software Version: N/A Product Description: Thunderbeat instrument is a sterile, single use item which is intended to be used with the Ultrasonic Generator (USG-400), the Electrosurgical Generator (WSG-400), and the Thunderbeat Transducer, (TD-TB400).
Product code
LFL Instrument, Ultrasonic Surgical
Reason for recall
The probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
FDA root cause
Under Investigation by firm
Action
On December 20, 2024, URGENT FIELD SAFETY NOTICE: ADVISORY letters were sent to customers. Actions Required: Olympus requires you to take the following actions: 1. Carefully read the content of this FSN. 2. Ensure all personnel are completely knowledgeable and thoroughly trained on the content of this FSN and the relevant IFU. 3. Olympus requests that you acknowledge receipt of this FSN through our web portal: a. Go to https://olympusamerica.com/recall b. Enter the recall number "0462 c. Complete the form as instructed and include your account ID number: [XXXXXXXX] d. Indicating in the comments if you would like to receive in-service training to support the correct use of this device. 4. If you have further distributed this product, identify your customers, and forward this FSN to them. Olympus requests that you report any complaints, including probe damage or pad detachment, to Technical Assistance Center (TAC) at 1- 800-848-9024 (option 1), and the FDA. Adverse events experienced with the use of this product may also be reported to the FDA s MedWatch Adverse Event Reporting program either online, by regular mail, or by fax. Olympus fully appreciates your prompt cooperation. If you require additional information, please do not hesitate to contact me by phone at (647) 999-3203 or by e-mail at [email protected].
Quantity in commerce
128,608 units (OUS ONLY)
Distribution
US Nationwide distribution and International: Algeria, Armenia, Australia, Austria, Azerbaijan, Bangladesh, Belarus, Belgium, Belize, Benin, Bolivia, Bosnia-Herz., Brazil, Bulgaria, Burkina Faso, Cambodia, Canada, Chile, China, Costa Rica, Cote d'Ivoire, Croatia, Cyprus, Czech Republic, Denmark, Dominican Republic, Estonia, Finland, France, Georgia, Germany, Ghana, Greece, Guatemala, Guernsey, Honduras, Hong Kong, Hungary, Iceland, India, Indonesia, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Kenya, Korea, Kuwait, Latvia, Lithuania, Luxembourg, Malaysia, Mauritius, Mexico, Montenegro, Morocco, Nepale, Netherlands, New Zealand, Nigeria, Norway, Oman, Pakistan, Panama, Paraguay, Peru, Philippines, Poland, Portugal, Qatar, Romania, Saudi Arabia, Senegal, Serbia, Singapore, Slovakia, Slovenia, South Africa, Spain, Sri Lanka, Sweden, Switzerland, Thailand, Tunisia, Turkey, Ukraine, United Kingdom, Uruguay, Utd.Arab Emir., Vietnam, Yemen.
Product codes and lots
Model: TB-0535FCS; Catalog Number/Product Code: N5423730; UDI: 04953170383557, 04953170383554; Lots: All

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0996-2025
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0993-2025Class IIOngoingVoluntary: Firm initiated
Z-0994-2025Class IIOngoingVoluntary: Firm initiated
Z-0995-2025Class IIOngoingVoluntary: Firm initiated
Z-0996-2025Class IIOngoingVoluntary: Firm initiated
Z-0997-2025Class IIOngoingVoluntary: Firm initiated
Z-0998-2025Class IIOngoingVoluntary: Firm initiated
Z-0999-2025Class IIOngoingVoluntary: Firm initiated
Z-1000-2025Class IIOngoingVoluntary: Firm initiated
Z-1001-2025Class IIOngoingVoluntary: Firm initiated
Z-1002-2025Class IIOngoingVoluntary: Firm initiated
Z-1003-2025Class IIOngoingVoluntary: Firm initiated