CENTURION Infusion Catheter, 7F, 17cm (DO), Reorder MIC17F7; Infusion Catheter with Antimicrobial Heparin...
MEDLINE INDUSTRIES, LP - Northfield began a recall of CENTURION Infusion Catheter, 7F, 17cm (DO), Reorder MIC17F7; Infusion Catheter with Antimicrobial Heparin Coating on . FDA classified it as Class II and gives the reason as "Certain lots Sterile Infusion Catheters which were mislabeled as having a heparin coating were either distributed or manufactured into medical convenience kits and distributed". As of , the recall status on record is Open, Classified, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-1048-2025
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- MEDLINE INDUSTRIES, LP - Northfield
- Product
- CENTURION Infusion Catheter, 7F, 17cm (DO), Reorder MIC17F7; Infusion Catheter with Antimicrobial Heparin Coating.
- Product code
- DYB Introducer, Catheter
- Reason for recall
- Certain lots Sterile Infusion Catheters which were mislabeled as having a heparin coating were either distributed or manufactured into medical convenience kits and distributed.
- Root cause tag
- labeling and UDI
- FDA root cause
- Process change control
- Action
- Medline Industries, LP issued one IMMEDIATE ACTION REQUIRED notice and one MEDICAL DEVICE RECALL notice to its affected consignees on 12/23/2024 via email and US Mail. The IMMEDIATE ACTION REQUIRED notice explained the labeling issue with the device, potential risk, and requested the following actions be taken: 1. affected catheters be quarantined, 2. respond with quantity on hand, 3. if the product was transferred to notify those to whom the affected catheters were transferred. Upon receipt of the response. Medline will issue corrected labeling to affix to the devices. The MEDICAL DEVICE RECALL notice, which pertains to kits manufactured with the affected catheters as a component, also explained the labeling issue with the device, potential risk, and requested the following actions be taken: 1. affected catheters be quarantined, 2. respond with quantity on hand, 3. if the product was transferred to notify those to whom the affected catheters were transferred. Upon receipt of the response. Medline will issue a label to affix to the devices which will state the affected component shall be removed and discarded from further use.
- Quantity in commerce
- 1200 units
- Distribution
- US: FL, KS, ND, PA, WA, WV, IL, WA
- Product codes and lots
- UDI/DI 10653160249979 (EA) 20653160249976 (CS), Lot Numbers: 2024103190, 2024050990, 2024021290, 2024012990, 2024111990
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1048-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1049-2025 | Class II | Ongoing | Voluntary: Firm initiated |