Z-2056-2025Class II

Philips L8-4 Transducer

Philips North America LLC / initiated 2025-05-28 / Open, Classified / root cause: manufacturing process

Philips Ultrasound, Inc began a recall of Philips L8-4 Transducer on . FDA classified it as Class II and gives the reason as "Ultrasound transducer devices were refurbished beyond their useful life". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2056-2025
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Philips North America LLC
Product
Philips L8-4 Transducer.
Product code
ITX Transducer, Ultrasonic, Diagnostic
Reason for recall
Ultrasound transducer devices were refurbished beyond their useful life.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
An URGENT Medical Device Recall notification dated 5/28/25 was mailed to consignees. The notification informs consignees that Philips Ultrasound will be replacing transducers that were refurbished beyond their useful life with a new transducer. Consignees may continue to use affected devices while awaiting replacement; consignees should use devices in accordance with their intended use and per the instructions provided int he User Manual. Users should perform visual inspection and electrical safety testing as indicated in the User Manual; if a device does not pass inspection, it should be removed from clinical use. Consignees are asked to return the completed Response Form and circulate the provided notification to all users to ensure awareness. A copy of the recall notification should be kept with affected transducers until their replacement. Consignees with any questions can contact the Customer Care Solutions Center at 1-800-722-9377. Additional consignees were identified and notified via URGENT Medical Device Recall Notification on 9/5/25.
Quantity in commerce
5,230 units
Distribution
Domestic: Nationwide Distribution; Foreign: Australia, Austria, Belgium, Brazil, Bulgaria, Canada, Chile, China, Colombia, Czech Republic, Denmark, Egypt, Finland, France, Germany, Greece, Hong Kong, Hungary, India, Indonesia, Iran, Ireland, Israel, Italy, Japan, Jordan, Latvia, Lebanon, Luxembourg, Malaysia, Mexico, Morocco, Netherlands, New Caledonia, New Zealand, Nicaragua, Oman, Philippines, Poland, Portugal, Romania, Russian Fed., Saudi Arabia, Singapore, South Africa, South Korea, Spain, Sri Lanka, Sweden, Switzerland, Taiwan, Thailand, T¿rkiye, United Kingdom, United Arab Emirates, Venezuela, Vietnam.
Product codes and lots
Model No. 989605440811, 989605440812; UDI: (01)00884838067684(21)B0LZNN, (01)00884838067684(21)03BPVM, (01)00884838067684(21)02KMFZ, (01)00884838067684(21)02HJDK, (01)00884838067684(21)02FWNQ, (01)00884838067684(21)02KKZT, (01)00884838067684(21)03H7GL, (01)00884838067684(21)02LTKK, (01)00884838067684(21)02H2JM, (01)00884838067684(21)02KKVB, (01)00884838067684(21)038XYV, (01)00884838067684(21)02DLVR, (01)00884838067684(21)02CCM5, (01)00884838067684(21)02LT6G, (01)00884838067684(21)02KMKK, (01)00884838067684(21)02V8VD, (01)00884838067684(21)037Z2B, (01)00884838067684(21)02NK5J; Serial No. B0LZNN, 03BPVM, 02KMFZ, 02HJDK, 02KLBP, 02FWNQ, 02RTF9, 02KKZT, 03H7GL, 02LTKK, 02H2JM, 02KKVB, 038XYV, 02H34T, 02DLVR, 02CCM5, 02LT6G, 02KMKK, 02V8VD, 02JC66, 02V016, 037Z2B, 02NK5J.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2056-2025
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2048-2025Class IIOngoingVoluntary: Firm initiated
Z-2049-2025Class IIOngoingVoluntary: Firm initiated
Z-2050-2025Class IIOngoingVoluntary: Firm initiated
Z-2051-2025Class IIOngoingVoluntary: Firm initiated
Z-2052-2025Class IIOngoingVoluntary: Firm initiated
Z-2053-2025Class IIOngoingVoluntary: Firm initiated
Z-2054-2025Class IIOngoingVoluntary: Firm initiated
Z-2055-2025Class IIOngoingVoluntary: Firm initiated
Z-2056-2025Class IIOngoingVoluntary: Firm initiated
Z-2057-2025Class IIOngoingVoluntary: Firm initiated
Z-2058-2025Class IIOngoingVoluntary: Firm initiated
Z-2059-2025Class IIOngoingVoluntary: Firm initiated
Z-2060-2025Class IIOngoingVoluntary: Firm initiated
Z-2061-2025Class IIOngoingVoluntary: Firm initiated
Z-2062-2025Class IIOngoingVoluntary: Firm initiated
Z-2063-2025Class IIOngoingVoluntary: Firm initiated
Z-2064-2025Class IIOngoingVoluntary: Firm initiated
Z-2065-2025Class IIOngoingVoluntary: Firm initiated
Z-2066-2025Class IIOngoingVoluntary: Firm initiated
Z-2067-2025Class IIOngoingVoluntary: Firm initiated
Z-2068-2025Class IIOngoingVoluntary: Firm initiated