Z-2473-2025Class II

STA Satellite

Diagnostica Stago, Inc. / initiated 2025-07-21 / Open, Classified

Diagnostica Stago, Inc. began a recall of STA Satellite. Product Code: All references. All software versions. The STA Satellite is a fully automated benchtop analyzer capable of simultaneously... on . FDA classified it as Class II and gives the reason as "Potential for contamination of STA-LIQUID ANTI-Xa by Stago Fibrinogen reagents in UFH and LMWH applications". As of , the recall status on record is Open, Classified.

Recall record

Recall number
Z-2473-2025
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Diagnostica Stago, Inc.
Product
STA Satellite. Product Code: All references. All software versions. The STA Satellite is a fully automated benchtop analyzer capable of simultaneously performing clotting, chromogenic, and immunologic assays.
Product code
JPA System, Multipurpose For In Vitro Coagulation Studies
Reason for recall
Potential for contamination of STA-LIQUID ANTI-Xa by Stago Fibrinogen reagents in UFH and LMWH applications.
FDA root cause
Mixed-up of materials/components
Action
Diagnostica Stago notified consignees on about 07/21/2025 via emailed letter titled URGENT: MEDICAL DEVICE RECALL (CORRECTION). Consignees were instructed to temporarily systematically run a quality control just before a batch of UFH or LMWH, if you run STA-LIQUID ANTI-Xa in UFH and LMWH applications on your STA SATELLITE analyzer. This request is being asked while Stago works to develop a permanent solution for the analyzer. Consignees were also requested to complete and return the Acknowledgement Form and to notify customers if affected units were transferred or further distributed.
Quantity in commerce
3,650 units (538 US)
Distribution
Worldwide - US Nationwide distribution in the states of AL, AZ, CA, CO, FL, GA, LA, MD, ME, MN, MO, MT, NC, OH, OK, OR, PA, PR, SD, VT, WI, WY and the countries of Algeria, Argentina, Austria, Brazil, Bulgaria, Canada, Chile, Colombia, Costa Rica, France, French Polynesie, Guadeloupe, India, Iran, Israel, Jordan, Korea, Kuwait, Lebanon, Malaysia, Mexico, Morocco, Netherlands, Oman, Paraguay, Peru, Republique Tcheque, Romania, Saudi Arabia, Serbia, South Africa, Switzerland, Taiwan, Thailand, Tunisia, Turquie, United Arab Emirates, Uruguay, Vietnam.
Product codes and lots
Product Code: All references. UDI-DI: 03607450581041, 03607450581027. All software versions.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2473-2025
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2473-2025Class IIOngoingVoluntary: Firm initiated
Z-2474-2025Class IIOngoingVoluntary: Firm initiated
Z-2475-2025Class IIOngoingVoluntary: Firm initiated
Z-2476-2025Class IIOngoingVoluntary: Firm initiated