Z-2548-2025Class II
Brand Name: DJO SURGICAL Product Name: ALTIVATE REVERSE WEDGE GLENOID REAMER SLEEVE Model/Catalog Number...
Encore Medical, LP / initiated 2025-07-18 / Open, Classified / root cause: design
Encore Medical, LP began a recall of Brand Name: DJO SURGICAL Product Name: ALTIVATE REVERSE WEDGE GLENOID REAMER SLEEVE Model/Catalog Number: 804-06-310 Product Description: Material: S.S/CoCrMo... on . FDA classified it as Class II and gives the reason as "Their is a potential that the reamer may kick or bind up during or immediately prior to use". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-2548-2025
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- Encore Medical, LP
- Product
- Brand Name: DJO SURGICAL Product Name: ALTIVATE REVERSE WEDGE GLENOID REAMER SLEEVE Model/Catalog Number: 804-06-310 Product Description: Material: S.S/CoCrMo, Non-Sterile
- Product code
- KWS Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
- Reason for recall
- Their is a potential that the reamer may kick or bind up during or immediately prior to use.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- On July 29, 2025, Enovis issued a "Urgent Medical Device Recall Notification via Email to affected consignees. On August 4, 2025, Enovis issued an update to the recall notification via E-Mail requesting consignees rework affected trays and returned affected products. Enovis asked consignees to take the following actions: 1. Continue using the wedge reamer assembly while carefully inspecting and following the specific details in the supplied Quality Bulletin. 2. This notice needs to be passed on to all those within your organization or to any organization where the product has been transferred. 3. Please see the attached quality Bulletin 4. By 9/13/25, the firm will reach out regarding reworking and returning trays. 5. Acknowledge receipt of notification.
- Quantity in commerce
- 447 units
- Distribution
- US Nationwide distribution in the states of AL, AZ, CA, CO, FL, HI, IA, IL, IN, KS, KY, LA, MD, ME, NE, NJ, NY, OH, PR, RI, SC, TN, TX, UT, VA, WA, WI.
- Product codes and lots
- Lot Code: All Lots GTIN: 00190446843818
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2546-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2547-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2548-2025 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-2549-2025 | Class II | Ongoing | Voluntary: Firm initiated |