Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-0555-2026Class II

SAFE-T-FILL MicroHematocrit Capillary Tubes, 50 L; Plastic, Ammonium Heparinized, Red Marking Model/Catalog...

ASP Global, LLC / initiated 2025-09-26 / Open, Classified / root cause: manufacturing process

ASP Global, LLC. dba Anatomy Supply Partners, LLC. began a recall of SAFE-T-FILL MicroHematocrit Capillary Tubes, 50 L; Plastic, Ammonium Heparinized, Red Marking Model/Catalog Number: 06 0507 Product Description: A clear... on . FDA classified it as Class II and gives the reason as "Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0555-2026
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
ASP Global, LLC
Product
SAFE-T-FILL MicroHematocrit Capillary Tubes, 50 L; Plastic, Ammonium Heparinized, Red Marking Model/Catalog Number: 06 0507 Product Description: A clear, plastic capillary blood collection tube coated with Heparin
Product code
GIO Tube, Collection, Capillary Blood
Reason for recall
Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes.
Root cause tag
manufacturing process
FDA root cause
Process change control
Action
On 09/26-29/2025, ASP Global emailed an URGENT MEDICAL DEVICE RECALL Letter to customers. ASP Global, LLC, is voluntarily recalling all RAM Scientific SAFE-T-FILL products within remaining expiry. ASP Global was made aware that our contract manufacturer for the RAM Scientific SAFE-T-FILL products was issued an FDA Warning Letter citing significant violations of the Quality System requirements, including inadequate production and process controls, as well as design controls. Customers are instructed to: a) Discontinue use of the recalled products immediately. b) Quarantine any remaining inventory to prevent further use. c) If critical or abnormal test results were obtained using the affected SAFE-T-FILL products, ensure they are verified through repeat or confirmatory testing in accordance with institutional protocols (e.g., venous confirmation of abnormal pediatric screening results). d) Dispose remaining inventory in accordance with your local facility guidelines or notify ASP Global at [email protected] for return authorization and disposal. e) Complete and return the Recall Response Form to confirm receipt and actions to [email protected]. For questions or assistance - contact [email protected] (855)-867-2190| Mon Fri, 9:00 AM 5:00 PM ET
Quantity in commerce
2000
Distribution
Distribution US nationwide and Canada.
Product codes and lots
Model Number: 06 0507 GTIN (Inner Pack): 30643351000391 UDI-DI: 10643351000397 All Lots produced from 31JUL2023 to 28FEB2025: 24B4200

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0555-2026
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0544-2026Class IIOngoingVoluntary: Firm initiated
Z-0545-2026Class IIOngoingVoluntary: Firm initiated
Z-0546-2026Class IIOngoingVoluntary: Firm initiated
Z-0547-2026Class IIOngoingVoluntary: Firm initiated
Z-0548-2026Class IIOngoingVoluntary: Firm initiated
Z-0549-2026Class IIOngoingVoluntary: Firm initiated
Z-0550-2026Class IIOngoingVoluntary: Firm initiated
Z-0551-2026Class IIOngoingVoluntary: Firm initiated
Z-0552-2026Class IIOngoingVoluntary: Firm initiated
Z-0553-2026Class IIOngoingVoluntary: Firm initiated
Z-0554-2026Class IIOngoingVoluntary: Firm initiated
Z-0555-2026Class IIOngoingVoluntary: Firm initiated
Z-0556-2026Class IIOngoingVoluntary: Firm initiated
Z-0557-2026Class IIOngoingVoluntary: Firm initiated
Z-0558-2026Class IIOngoingVoluntary: Firm initiated
Z-0559-2026Class IIOngoingVoluntary: Firm initiated
Z-0560-2026Class IIOngoingVoluntary: Firm initiated
Z-0561-2026Class IIOngoingVoluntary: Firm initiated
Z-0562-2026Class IIOngoingVoluntary: Firm initiated
Z-0563-2026Class IIOngoingVoluntary: Firm initiated
Z-0564-2026Class IIOngoingVoluntary: Firm initiated
Z-0565-2026Class IIOngoingVoluntary: Firm initiated
Z-0566-2026Class IIOngoingVoluntary: Firm initiated
Z-0567-2026Class IIOngoingVoluntary: Firm initiated