Z-1090-2026Class II

Medline medical procedure convenience kits labeled as: KIT ROBOTICS UROLOGY PROSTATE, REF DYKMBNDL116G

MEDLINE INDUSTRIES, LP - Northfield / initiated 2025-12-16 / Open, Classified / root cause: design

Medline Industries, LP began a recall of Medline medical procedure convenience kits labeled as: KIT ROBOTICS UROLOGY PROSTATE, REF DYKMBNDL116G on . FDA classified it as Class II and gives the reason as "Medline kits containing Stryker's Strykeflow 2 Suction Irrigators due to a change in design in 2024, irrigation solution is able to travel to the handpiece and battery pack during use of the Strykeflow 2 Suction...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.

Recall record

Recall number
Z-1090-2026
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
MEDLINE INDUSTRIES, LP - Northfield
Product
Medline medical procedure convenience kits labeled as: KIT ROBOTICS UROLOGY PROSTATE, REF DYKMBNDL116G
Product code
OKV Obstetrical Kit
Reason for recall
Medline kits containing Stryker's Strykeflow 2 Suction Irrigators due to a change in design in 2024, irrigation solution is able to travel to the handpiece and battery pack during use of the Strykeflow 2 Suction Irrigator. This design change has caused some devices to leak and/or emit vaporized saline (which can resemble smoke) during use.
Root cause tag
design
FDA root cause
Under Investigation by firm
Action
Medline Industries issued an URGENT MEDICAL DEVICE RECALL notice to its consignees on 12/16/2025 via email and USPS first class mail. The notice explained the issue, potential risk, and requested the following: "1.Immediately check your stock for the affected item number(s) and the affected lot number(s) listed within the recall portal. Quarantine all affected product. 2.Please use the link and the information below to complete your response form. Please list the quantityof affected product you have in inventory on the form. Even if you do not have any affected productin inventory, please complete and submit the form. Website link: https://recalls.medline.comRecall Reference #: R-25-145-FGX5 Recall Code: 3.Upon receipt of your submitted response form, your account will receive over-labels to place on affected inventory, with instructions for your staff to remove and discard the affected component prior to using the kit. These labels will be provided via FedEx overnight, if applicable. 4.If you are a distributor or have resold or transferred this product to another company or individual, you are required by FDA regulations to notify them of this recall communication. Please include your customers quantities on your response form. Upon receipt of your submitted response form, you will receive over-labels to provide to your customers to affix to their affected product. If you have any questions, contact the Recall Department at 866-359-1704 or [email protected]."
Quantity in commerce
12 units
Distribution
US Nationwide distribution.
Product codes and lots
UDI/DI 10198459156991 (EA) 40198459156992 (CS), Lot Number 25EBM426

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1090-2026
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1085-2026Class IIOngoingVoluntary: Firm initiated
Z-1086-2026Class IIOngoingVoluntary: Firm initiated
Z-1087-2026Class IIOngoingVoluntary: Firm initiated
Z-1088-2026Class IIOngoingVoluntary: Firm initiated
Z-1089-2026Class IIOngoingVoluntary: Firm initiated
Z-1090-2026Class IIOngoingVoluntary: Firm initiated