Z-1446-2026Class II

Olympus Resection Sheath, 28 Fr. with Deflecting Obturator. Model No. A22043T. Resection sheath for urologic...

OLYMPUS Corporation of the Americas / initiated 2025-11-11 / Open, Classified

Olympus Corporation of the Americas began a recall of Olympus Resection Sheath, 28 Fr. with Deflecting Obturator. Model No. A22043T. Resection sheath for urologic applications on . FDA classified it as Class II and gives the reason as "Complaints of the ceramic tip of the resection sheath breaking have been received". As of , the recall status on record is Open, Classified.

Recall record

Recall number
Z-1446-2026
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
OLYMPUS Corporation of the Americas
Product
Olympus Resection Sheath, 28 Fr. with Deflecting Obturator. Model No. A22043T. Resection sheath for urologic applications.
Product code
FJL Resectoscope
Reason for recall
Complaints of the ceramic tip of the resection sheath breaking have been received.
FDA root cause
Under Investigation by firm
Action
An URGENT MEDICAL DEVICE CORRECTIVE ACTION notice was sent to consignees 1/6/2026. Consignees are instructed to ensure all personnel are familiar with the contents of the notification. Users are to adhere to the Inspection and Testing and Caution sections of the IFU for both the resection/inner sheath, as well as the Inspection Before Each Use section in the Resectoscope System Manual. Additional instructions include having an extra resection sheath and inspect during and after procedure for device fragments. Consignees are to retain a copy of the notification with the IFU. Consignees with any questions may contact Cynthia Ow at [email protected] or by phone at 947-999-3203.
Quantity in commerce
207 units
Distribution
US Nationwide Distribution.
Product codes and lots
Model No. A22043T; UDI: 04042761021012; All Lots.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1446-2026
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1438-2026Class IIOngoingVoluntary: Firm initiated
Z-1439-2026Class IIOngoingVoluntary: Firm initiated
Z-1440-2026Class IIOngoingVoluntary: Firm initiated
Z-1441-2026Class IIOngoingVoluntary: Firm initiated
Z-1442-2026Class IIOngoingVoluntary: Firm initiated
Z-1443-2026Class IIOngoingVoluntary: Firm initiated
Z-1444-2026Class IIOngoingVoluntary: Firm initiated
Z-1445-2026Class IIOngoingVoluntary: Firm initiated
Z-1446-2026Class IIOngoingVoluntary: Firm initiated
Z-1447-2026Class IIOngoingVoluntary: Firm initiated
Z-1448-2026Class IIOngoingVoluntary: Firm initiated
Z-1449-2026Class IIOngoingVoluntary: Firm initiated
Z-1450-2026Class IIOngoingVoluntary: Firm initiated
Z-1451-2026Class IIOngoingVoluntary: Firm initiated
Z-1452-2026Class IIOngoingVoluntary: Firm initiated
Z-1453-2026Class IIOngoingVoluntary: Firm initiated
Z-1454-2026Class IIOngoingVoluntary: Firm initiated
Z-1455-2026Class IIOngoingVoluntary: Firm initiated
Z-1456-2026Class IIOngoingVoluntary: Firm initiated
Z-1457-2026Class IIOngoingVoluntary: Firm initiated