Brand Name: B. Braun Product Name: BBraun Medical 21G X4.4CM Winged INF Model/Catalog Number: 7B3050 Software...
B Braun Medical Inc began a recall of Brand Name: B. Braun Product Name: BBraun Medical 21G X4.4CM Winged INF Model/Catalog Number: 7B3050 Software Version: N/A Product Description: A device... on . FDA classified it as Class II and gives the reason as "The potential for the needle tip to be dull/blunt, difficult to advance, and/or break". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-1481-2026
- Classification
- Class II
- Status
- Open, Classified
- Initiated
- Posted
- Recalling firm
- B Braun Medical Inc
- Product
- Brand Name: B. Braun Product Name: BBraun Medical 21G X4.4CM Winged INF Model/Catalog Number: 7B3050 Software Version: N/A Product Description: A device designed for subcutaneous implantation and intended to be used temporarily to expand an implanted tissue expander by percutaneous injection of air or fluids. Component: N/A
- Product code
- LCJ Tissue Expander And Accessories
- Reason for recall
- The potential for the needle tip to be dull/blunt, difficult to advance, and/or break.
- Root cause tag
- manufacturing process
- FDA root cause
- Process control
- Action
- On February 2, 2026 URGENT MEDICAL DEVICE RECALL NOTIFICATION letters were sent to customers. Actions to be taken: 1. Review the notice in its entirety and ensure that all users in your organization are aware and informed about this voluntary recall. If you are a distributor and have further distributed the product, please forward this notice to your consignees. The recall is to be extended to the hospital/healthcare facility level. 2. Examine inventory for affected product, cease use and quarantine product subject to recall. Do not destroy any affected product. 5. Once we receive your Acknowledgement Form, a B. Braun Customer Support representative will contact you with instructions on how to return any impacted cases, including partial cases, in your possession and provide credit and/or replacement of the product based on your individual needs.
- Quantity in commerce
- 105550 units
- Distribution
- Worldwide - US Nationwide distribution in the state of TX and the country of Costa Rica.
- Product codes and lots
- Model/Catalog Number: 7B3050; Primary-DI 4046964341298, Unit of Use- DI 4046964341274; Lot 0062006430, Exp 30APR2032; Lot 0062006470, Exp 30JUN2032; Lot 0062006471, Exp 31MAY2032; Lot 0062014964, Exp 31JUL2032; Lot 0062014965, Exp 31JUL2032; Lot 0062014966, Exp 30SEP2032; Lot 0062027579, Exp 31AUG2032.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1481-2026 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1482-2026 | Class II | Ongoing | Voluntary: Firm initiated | ||
| Z-1483-2026 | Class II | Ongoing | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.
