Z-1576-2026Class I

ProGuide Chronic Dialysis Catheters, REF: DC01455550/C, DC21452419/C, DC21452419-NE5/C, DC21452823-NE5/C...

Merit Medical Systems, Inc. / initiated 2026-02-13 / Open, Classified / root cause: manufacturing process

Merit Medical Systems, Inc. began a recall of ProGuide Chronic Dialysis Catheters, REF: DC01455550/C, DC21452419/C, DC21452419-NE5/C, DC21452823-NE5/C, DC21454035/C, DC21455550/C on . FDA classified it as Class I and gives the reason as "16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-1576-2026
Classification
Class I
Status
Open, Classified
Initiated
Posted
Recalling firm
Merit Medical Systems, Inc.
Product
ProGuide Chronic Dialysis Catheters, REF: DC01455550/C, DC21452419/C, DC21452419-NE5/C, DC21452823-NE5/C, DC21454035/C, DC21455550/C
Product code
MSD Catheter, Hemodialysis, Implanted
Reason for recall
16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future vascular access.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
On 2/13/2026, recall notices were mailed and emailed to customers who were asked to do the following: A picture of the 16F Dual-Valved Splittable Sheath Introducer is attached to help you identify the product. Place this notice and the picture on or near the affected product in your inventory (if applicable). Discontinue the use of the 16F Dual-Valved Splittable Sheath Introducer and destroy the sheath introducer at the point of use. Ensure that applicable personnel within your organization are made aware of this field action. If the product has been further distributed to other facilities, institutions, or manufacturers, ensure this notice is immediately shared with them and note the quantity distributed on the customer response form. Complete and return the customer response form via email to [email protected] If you have any questions concerning this communication, contact the firm's Customer Service via email at [email protected] or via phone at +1 800 356 3748, Hours: 6 am to 6 pm MST, Mon-Fri. On 4/2/2026, revised notices were mailed to customers that included stickers to be placed on affected devices to ensure awareness of the recall.
Quantity in commerce
131
Distribution
Worldwide distribution: US (nationwide) to states of: TX, LA, OR, NM, MI, FL, CO, CA, GA, NC, AK, NY, PA, WI, NJ, VA, AZ, IN, KY, MO, DE, SC, MT, NE, WV, OH, MA, MN, CT, MD, KS, WA, TN, ID, UT, DC, MS, IL, OK, AL, RI, AR, NV and OUS (International) to countries of : Canada, Spain, United Arab Emirates, Brazil, Jordan, Iraq, France, Indonesia, Malaysia, Thailand, Slovakia, Colombia, Saudi Arabia, Belize, Hong Kong, Mexico, Austria, Belgium, Chile, Germany, Sweden, Ireland, Poland, Latvia, Italy, South Africa, Switzerland, Bulgaria, Peru, Argentina, Qatar, Greece, Georgia, United Kingdom, Brunei Darussalam, Ecuador, Panama, Netherlands, Venezuela, Bolivarian Republic of, Costa Rica, Viet Nam, Cayman Islands, Iran, Islamic Republic of, Australia, Nicaragua, Dominican Republic, Bolivia, Plurinational State of, El Salvador, Guatemala, Honduras, Japan
Product codes and lots
REF:UDI-DI/Lot(Expiration): DC01455550/C:00884450697870/H2600169; DC21452419/C:00884450697900/H2659228: DC21452419-NE5/C:00884450697894/H3249278): DC21452823/C:00884450697924/H2600164, H2628890; DC21452823-NE5/C:00884450697917/H2990807: DC21453227/C:00884450697948/H2630602; DC21454035/C:00884450697962/H2628887: DC21455550/C:00884450697979/H2630553, H2659229

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1576-2026
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1575-2026Class IOngoingVoluntary: Firm initiated
Z-1576-2026Class IOngoingVoluntary: Firm initiated
Z-1577-2026Class IOngoingVoluntary: Firm initiated
Z-1578-2026Class IOngoingVoluntary: Firm initiated
Z-1579-2026Class IOngoingVoluntary: Firm initiated