Z-2231-2026Class I

Medline kits containing Huons Co. Bupivacaine HCL in Dextrose Injection, USP, labeled as: 1) ANESTHESIA TRAY...

MEDLINE INDUSTRIES, LP - Northfield / initiated 2026-04-10 / Open, Classified / root cause: design

Medline Industries, LP began a recall of Medline kits containing Huons Co. Bupivacaine HCL in Dextrose Injection, USP, labeled as: 1) ANESTHESIA TRAY, Medline SKU DYNJRA1355A; 2) SPINAL ANESTHESIA... on . FDA classified it as Class I and gives the reason as "Medline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and...". As of , the recall status on record is Open, Classified, and MDM tags the root cause as design.

Recall record

Recall number
Z-2231-2026
Classification
Class I
Status
Open, Classified
Initiated
Posted
Recalling firm
MEDLINE INDUSTRIES, LP - Northfield
Product
Medline kits containing Huons Co. Bupivacaine HCL in Dextrose Injection, USP, labeled as: 1) ANESTHESIA TRAY, Medline SKU DYNJRA1355A; 2) SPINAL ANESTHESIA TRAY, Medline SKU DYNJRA2151.
Product code
CAI Circuit, Breathing (W Connector, Adaptor, Y Piece)
Reason for recall
Medline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and reported efficacy complaints.
Root cause tag
design
FDA root cause
Component design/selection
Action
Medline Industries, LP issued an URGENT MEDICAL DEVICE RECALL notice to its consignees on 4/10/2026 via USPS first class mail and email. The notice explained the issue with the component and requested the following: - Identify and quarantine the affected item and lot numbers (kit). - Respond to notice via the portal: Website link: https://recalls.medline.com, Recall Reference #: R-26-065-FGX1, using the Recall Code provided. - Once the response is received, over-labels will be provided to be placed on the affected inventory with instructions to remove and discard the affected component. - Distributors or those who have further distributed the product are directed to notify those to whom the affected kits were distributed and include the customers quantities on your response form. Upon receipt of your submitted response form, you will receive over-labels to provide to your customers to affix to their affected product. For questions, contact the Recall Department at 866-359-1704 or [email protected].
Quantity in commerce
1100 kits
Distribution
Worldwide - US Nationwide distribution in the US Territory of Virgin Islands and the countries of Bahamas, Panama, Barbados.
Product codes and lots
Medline SKU DYNJRA1355A: UDI/DI 10195327179830 each, FI case, Lot Numbers: 26CBA272; Medline SKU DYNJRA1355A: UDI/DI 10195327179830 each, FI case, Lot Numbers: 26ABS307; Medline SKU DYNJRA1355A: UDI/DI 10195327179830 each, FI case, Lot Numbers: 25HBE663; Medline SKU DYNJRA1355A: UDI/DI 10195327179830 each, FI case, Lot Numbers: 25FBA408; Medline SKU DYNJRA1355A: UDI/DI 10195327179830 each, FI case, Lot Numbers: 25CBG043; Medline SKU DYNJRA1355A: UDI/DI 10195327179830 each, FI case, Lot Numbers: 24FBT395; Medline SKU DYNJRA2151: UDI/DI 10195327365400 each, FI case, Lot Numbers: 24FBT396.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2231-2026
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2231-2026Class IOngoingVoluntary: Firm initiated
Z-2232-2026Class IOngoingVoluntary: Firm initiated
Z-2233-2026Class IOngoingVoluntary: Firm initiated
Z-2234-2026Class IOngoingVoluntary: Firm initiated
Z-2235-2026Class IOngoingVoluntary: Firm initiated
Z-2236-2026Class IOngoingVoluntary: Firm initiated
Z-2237-2026Class IOngoingVoluntary: Firm initiated