Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-0158-2027

Generic Name: GORE VIABIL Short Wire Biliary Endoprosthesis; Model/Catalog Number: VSWVH0808 and VSWVN1006...

W L Gore & Associates, Inc. / initiated 2026-09-03 / Open, Classified

Recall record

Recall number
Z-0158-2027
Status
Open, Classified
Initiated
Posted
Recalling firm
W L Gore & Associates, Inc.
Product
Generic Name: GORE VIABIL Short Wire Biliary Endoprosthesis; Model/Catalog Number: VSWVH0808 and VSWVN1006 Product Description: The GORE VIABIL Short Wire Biliary Endoprosthesis is a flexible, self-expanding endoprosthesis designed to maintain luminal patency of the common bile duct which may be obstructed. The endoprosthesis is radially compressed and secured onto the distal end of a catheter-based delivery system for deployment. The catheter provides a means for accessing and implanting the GORE VIABIL Short Wire Biliary Endoprosthesis at the target site in the biliary tract.
Product code
FGE Stents, Drains And Dilators For The Biliary Ducts
Reason for recall
The potential for the devices to be mislabeled with the incorrect length.
FDA root cause
Under Investigation by firm
Action
On September 8, 2026, URGENT MEDICAL DEVICE RECALL letters were sent to customers. Actions to be taken by the customer/user: Identify and return any unused devices within the scope of this recall for replacement. Please acknowledge receipt of this letter according to the instructions provided by our distributor, Olympus. This notice needs to be shared with those who should be aware within your institution or to any organization where potentially affected devices have been transferred (as appropriate). Implanting Physicians: If you have implanted one of the potentially mislabeled GORE VIABIL Short Wire Biliary Endoprosthesis devices, please be mindful of the potential health outcomes and plan to take the needed measures that could minimize any potential health hazards associated with this mislabeling. If a listed device has been used, please indicate the device(s) used when you acknowledge receipt according to the enclosed instruction from our distributor, Olympus
Quantity in commerce
32
Distribution
US Nationwide distribution in the states of GA, RI.
Product codes and lots
1. Model/Catalog Number: VSWVH0808; UDI-DI: 00733132638772; Lot Serial Numbers: 30907025, 30907033, 30907034, 30907036, 30907023, 30907024, 30907026, 30907027, 30907028, 30907029 (complaint device), 30907030, 30907031, 30907032 (complaint device), 30907035, 30907037, 30907038; 2. Model/Catalog Number: VSWVN1006; UDI-DI: 00733132638864; Lot Serial Numbers: 30843556, 30843557, 30843558, 30843559, 30843560, 30843561, 30843562, 30843563, 30843564, 30843565, 30843566, 30843567, 30843568, 30843569, 30843570, 30843571;