Z-0443-05
Anesthesia Set, product code 2C9216; a sterile fluid path consisting of a 72'' long PVC with DEHP tubing with...
Baxter Healthcare Corporation / initiated 2004-12-20 / Terminated / root cause: labeling and UDI
Baxter Healthcare Corp. began a recall of Anesthesia Set, product code 2C9216; a sterile fluid path consisting of a 72'' long PVC with DEHP tubing with a green stripe, inner diameter of 0.040''... on . The reason FDA records is "The anesthesia set was incorrectly labeled as an anti-siphon set, but the set does not contain an anti-siphon component". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-0443-05
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Baxter Healthcare Corporation
- Product
- Anesthesia Set, product code 2C9216; a sterile fluid path consisting of a 72'' long PVC with DEHP tubing with a green stripe, inner diameter of 0.040'', priming volume 1.7 mL, with a luerlock connector with fixed collar; 60 sets per case
- Product code
- FRN Pump, Infusion
- Reason for recall
- The anesthesia set was incorrectly labeled as an anti-siphon set, but the set does not contain an anti-siphon component.
- Root cause tag
- labeling and UDI
- FDA root cause
- Other
- Action
- Urgent Product Recall letters dated 12/20/04 were sent to the direct accounts on the same date via next day air. The accounts were informed that the sets were incorrectly labeled as anti-siphon sets and were requested to immediately discontinue use of the affected lot numbers of product code 2C9216 and return the sets to Baxter c/o NNC Group, 2670 Executive Dr., Indianapolis, IN 46241, following the enclosed instructions. A matrix containing key attributes of product code 2C9216 and two other product codes was provided for consideration of alternates to the recalled product. Any questions concerning the return process were directed to NCC at 1-800-300-5085. Any medical or technical questions were directed to Baxter at 1-800-422-9837. Wholesalers were requested to conduct sub-recalls from their sub-accounts.
- Quantity in commerce
- 485,197 sets
- Distribution
- Nationwide and internationally to Canada, Switzerland, Saudi Arabia and Kyrgyzstan
- Product codes and lots
- lots UR192765, UR192815, UR192856, UR194290, UR200097, UR200964, UR203109, UR204693, UR208017, UR208116, UR208371, UR209569, UR209791, UR213769, UR215699, UR217141, UR218172, UR218560, UR218669, UR218982, UR222679, UR224584, UR225227, UR227884, UR228353, UR229310, UR232892, UR233841, UR234443, UR234666, UR236554, UR236588, UR239087